Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: HARRIS TRUCKING & CONCRETE CONSTRUCTION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARRIS TRUCKING & CONCRETE CONSTRUCTION INC in 3512 HIGHWAY 5 N, BRYANT, AR 72019 (NAICS 238110). OSHA activity number 342162823.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harris Trucking & Concrete Construction INC for free Get an email when a new federal OSHA severe-injury report for Harris Trucking & Concrete Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
3512 HIGHWAY 5 N
City
BRYANT
State
AR
ZIP
72019
Mailing
206 BOYD STREET, PLUMERVILLE, AR 72127
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  On or about March 9, 2017 and times prior thereto, employees worked from a supported scaffold to perform concrete finishing which had excessive spacing greater than 1 inch between the platform and the uprights. This practice created conditions which exposed the employees to greater than 10 ft. fall hazards to the unfinished ground below.
Recent events (1)
  • · Z (S) $4183

1926.451 G04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:   On or about March 9, 2017 and times prior thereto, employees were working from a supported scaffold which did not have a guardrail system installed along all open sides and ends of the scaffold.
Recent events (1)
  • · Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 19, 2017
Abate by
May 3, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:   On or about March 9, 2017 and times prior thereto, employees on a supported scaffold were using the end frames and crossbraces of the scaffold as a means of access to the top of the bank vault.
Recent events (1)
  • · Z (S) $4183

1926.416 E01

Other-than-serious 1 instance 5 exposed
Issued
Apr 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:   On or about March 9, 2017 and times prior thereto, at the job site, employee(s) operated a Skilsaw electrical power tool in which its power cords outer sheath and insulation was torn, exposing the cord conductors underneath. This condition exposed employees to an electrical shock hazard.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342162823.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.