COLUMBIA FALLS, MT ·
OSHA Inspection: GLACIER CORP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GLACIER CORP, INC. in 455 FOURTH AVENUE E.N., COLUMBIA FALLS, MT 59912 (NAICS 321911). OSHA activity number 342169992.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLACIER CORP, INC.
- Site address
- 455 FOURTH AVENUE E.N.
- City
- COLUMBIA FALLS
- State
- MT
- ZIP
- 59912
- Mailing
- PO BOX 2609, COLUMBIA FALLS, MT 59912
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 7
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $1,847 · Current $924 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Shop: On March 14, 2017 and at times prior, employees were exposed to caught-in hazards while utilizing an unguarded Foremost Machinery 16-Speed Heavy Duty Drill Press.
Recent events (2)
- · I (S) $923.5
- · Z (S) $1847
1910.212 B
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Maintenance Shop: On March 14, 2017 and at times prior, employees were exposed to caught-under hazards while utilizing an unsecured Foremost Machinery 16-Speed Heavy Duty Drill Press.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.213 C01
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $2,309 · Current $1,155 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Shop: On March 14, 2017 and at times prior, employees were exposed to amputation hazards while ripping grained lumber on an unguarded Cantek table saw.
Recent events (2)
- · I (S) $1154.5
- · Z (S) $2309
1910.213 C02
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Shop: On March 14, 2017 and at times prior, employees were exposed to struck-by hazards while ripping grained lumber on an unguarded Cantek table saw.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.213 C03
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut: a) Shop: On March 14, 2017 and at times prior, employees were exposed to being struck by lumber kicking back while ripping grained lumber with an unguarded Cantek table saw.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 A02
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $1,847 · Current $924 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) Grinding Room: On March 14, 2017 and at times prior, employees were exposed to caught-in hazards while using an unguarded bench grinder.
Recent events (2)
- · I (S) $923.5
- · Z (S) $1847
1910.215 B09
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Grinding Room: On March 14, 2017 and at times prior, employees were exposed to struck-by hazards while using a United Tool Company bench grinder with the tongue guard set at approximately 3/4 inches.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $1,385 · Current $693 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Shop: On March 14, 2017 and at times prior, employees were exposed to shock and fire related hazards while using a relocatable power tap for permanent wiring to energize the items such as, but not limited to; air solenoid valves, lights, and a router.
Recent events (2)
- · I (S) $692.5
- · Z (S) $1385
1910.305 B02 I
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Green Press: On March 14, 2017 and at times prior, employees were exposed to fire hazards from an exposed 110 volt electrical outlet box supplying electrical energy to work lights.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Jamb Area: On March 14, 2017 and at times prior, employees were exposed to shock and fire hazards while working in and around an air solenoid that was supplied electrical energy by an orange flexible cord. b) Jamb Area: On March 14, 2017 and at times prior, employees were exposed to shock and fire hazards while working in and around a yellow flexible cord that supplied electrical energy to a three way outlet adapter, a work light, and a router.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 II
- Issued
- Jul 20, 2017
- Abate by
- Aug 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Jamb Area: On March 14, 2017 and at times prior, employees were exposed to shock and fire hazards while working in and around an air solenoid energized by an orange flexible cord. b) Jamb Area: On March 14, 2017 and at times prior, employees were exposed to shock and fire hazards while working in and around a yellow flexible cord energizing a three way outlet adapter, a work light, and a router. c) Grinding Room: On March 14, 2017 and at times prior, employees were exposed to shock and fire hazards while working in and around lights energized by an orange flexible cord, a white flexible cord, and a blue white and black conductor.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 321911)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342169992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.