Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: SAMPSON CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SAMPSON CONSTRUCTION in 530 N 17TH ST, LINCOLN, NE 68502 (NAICS 236220). OSHA activity number 342171014.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sampson Construction for free Get an email when a new federal OSHA severe-injury report for Sampson Construction is published. One employer, no account, unsubscribe in one click.
Site address
530 N 17TH ST
City
LINCOLN
State
NE
ZIP
68502
Mailing
3730 S 14TH ST, LINCOLN, NE 68502
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
300
Ownership type
Private (A)

2 citations on file for this inspection.

1926.1052 C01 II

Other-than-serious 1 instance 2 exposed
Issued
Apr 21, 2017
Penalty
Initial $11,408 · Current $11,408
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge.    The employer is failing to protect employees from fall hazards associated with working on a stairway without a stair rail system.  The most recent occurrence of this was evident during the inspection of the facility located at 530 N. 17th Street, Lincoln, NE; where employees were in the process of building a stairway that had 13 risers and was not equipped with a stair rail system.
Recent events (3)
  • · F (O) $11408
  • · C (S) $11408
  • · Z (S) $11408

1926.1052 C12

Other-than-serious 1 instance 2 exposed
Issued
Apr 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926:    The employer is failing to protect employees from fall hazards associated with working on a stairway landing that did not have a guardrail system on its unprotected sides and edges.  The most recent occurrence of this was evident during the inspection of the facility located at 530 N. 17th St, Lincoln, NE; where the employees were installing wooden steps on a staircase.  The employees were standing on a stairway landing that was over 9' high, was under construction and its sides and edges were not protected with a guard rail system.
Recent events (3)
  • · F (O) $0
  • · C (S) $0
  • · Z (S) $0

View Sampson Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342171014.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.