AGAWAM, MA ·
OSHA Inspection: NORTH AMERICAN INDUSTRIAL SERVICES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORTH AMERICAN INDUSTRIAL SERVICES, INC. in 188 M STREET, AGAWAM, MA 01001 (NAICS 561790). OSHA activity number 342177318.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTH AMERICAN INDUSTRIAL SERVICES, INC.
- Site address
- 188 M STREET
- City
- AGAWAM
- State
- MA
- ZIP
- 01001
- Mailing
- 1240 SARATOGA ROAD, BALLSTON SPA, NY 12020
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- Employees
- 580
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.28 B03 II
- Issued
- Aug 14, 2017
- Abate by
- Dec 21, 2018
- Penalty
- Initial $9,054 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(ii): Each employee was not protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems: Tertiary ash hopper top, Boiler #1, 188 Main Street, Agawam, MA: On or about March 15, 2017 the employer did not ensure each employee was protected from tripping into or through a floor hole that was less than 4 feet above the next lower level while conducting ash removal activities by means of covers or guardrails. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (3)
- · F (O) $2500
- · C (S) $9054
- · Z (S) $9054
1910.146 D02
- Issued
- Aug 14, 2017
- Abate by
- Dec 21, 2018
- Penalty
- Initial $12,675 · Current $12,934
General-duty citation text
29 CFR 1910.146(d)(2): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not identify and evaluate the hazards of permit spaces before employees enter: 188 Main Street, Agawam, MA: On or about March 15, 2017 the employer had not identified and evaluated the hazards associated with engulfment and thermal hazards prior to entry of the permit required confined space located in the tertiary chamber of boiler #1 exposing employees to engulfment and serious burn injuries. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (3)
- · F (S) $12934
- · C (S) $12675
- · Z (S) $12675
1910.146 D04 I
- Issued
- Aug 14, 2017
- Abate by
- Dec 21, 2018
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide, at no cost to the employees, testing and monitoring equipment needed to comply with 29 CFR 1910.146(d)(5): Tertiary, boiler#1, 188 Main Street, Agawam, MA: On or about March 15, 2017 the employer had not provided a thermal measuring device to monitor ash temperature during the vacuuming process which exposes hot ash capable of engulfing and burning employees. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (3)
- · F (S) $0
- · C (S) $12675
- · Z (S) $12675
1910.146 D04 IV
- Issued
- Aug 14, 2017
- Abate by
- Dec 21, 2018
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(d)(4)(iv): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide personal protective equipment in so far as feasible engineering and work practice controls did not adequately protect employees: Tertiary, Boiler #1, 188 Main Street, Agawam, MA: On or about March 15, 2017 the employer did not provide personal protective equipment for the body to protect employees from thermal hazards associated with removal of hot ash during boiler maintenance activities. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (3)
- · F (S) $0
- · C (S) $12675
- · Z (S) $12675
More inspections at North American Industrial Services, INC.
View North American Industrial Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561790)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342177318.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.