Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: R & L SPRING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R & L SPRING COMPANY in 1097 GENEVA PARKWAY, LAKE GENEVA, WI 53147 (NAICS 332613). OSHA activity number 342178068.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & L Spring Company for free Get an email when a new federal OSHA severe-injury report for R & L Spring Company is published. One employer, no account, unsubscribe in one click.
Site address
1097 GENEVA PARKWAY
City
LAKE GENEVA
State
WI
ZIP
53147
Mailing
1097 GENEVA PARKWAY, LAKE GENEVA, WI 53147
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332613
Employees
200
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 D01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 1, 2017
Abate by
Oct 13, 2017
Penalty
Initial $11,408 · Current $0 Reduced
29 CFR 1910.147(d)(1): Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.    On or about March 10, 2017, employee(s) did not utilize energy control procedures during servicing and/or maintenance activities of the BOBBIO-CNC-1400 in the F-60 department.  The list of these activities includes, but is not limited to, maintaining set up and replacing an arbor.
Recent events (2)
  • · I (S) $0
  • · Z (S) $11408

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $11,408 · Current $11,408
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):(a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) (IDENTIFY MACHINERY OR EQUIPMENT AND DESCRIBE HAZARD AND METHOD USED)Note:  Cite for cord and plug connected equipment that was not unplugged to isolate from energy source.   On or about March 10, 2017, employee(s) did not operate energy isolating devices so as to isolate energy sources during serving and/or maintenance activities on BOBBIO-CNC-1400 in the F-60 department.  The list of these activities includes, but is not limited to, maintaining set up and replacing an arbor.
Recent events (2)
  • · I (S) $11408
  • · Z (S) $11408

1910.147 D04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or about March 10, 2017, Lockout devices were not affixed to electrical disconnects during servicing and/or maintenance activities BOBBIO-CNC-1400 in the F-60 department.  The list of these activities includes, but is not limited to, maintaining set up and replacing an arbor.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C04 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 1, 2017
Abate by
Sep 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   The company's machine specific energy controls procedure did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques for the BOBIO-CNC- 1400 machine.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342178068.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.