Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: KBP COIL COATERS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KBP COIL COATERS in 3600 E 44TH AVE, DENVER, CO 80216 (NAICS 332812). OSHA activity number 342181781.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KBP Coil Coaters for free Get an email when a new federal OSHA severe-injury report for KBP Coil Coaters is published. One employer, no account, unsubscribe in one click.
Establishment
KBP COIL COATERS
Site address
3600 E 44TH AVE
City
DENVER
State
CO
ZIP
80216
Mailing
3600 E 44TH AVE, DENVER, CO 80216
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
42
Ownership type
Private (A)

5 citations on file for this inspection.

1910.28 B01 I

Other-than-serious 2 instances 2 exposed
Issued
Aug 9, 2017
Abate by
Aug 29, 2017
Penalty
Initial $5,926 · Current $2,963 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:    (a)  KBP Coil Coaters @ 3600 E 44th Ave. Denver, CO: On or before March 15, 2017, the employer did not ensure that the side of the elevated work platform above the tower that overlooks the rollers and roller carriage was equipped with a mid-rail. This condition exposed employees to a fall hazard of 20 feet, and the potential for a fallen employee to be caught in the moving parts in the tower accumulator.    (b)  KBP Coil Coaters @ 3600 E 44th Ave. Denver, CO:  On or before March 15, 2017, the employer did not ensure that the opening in the tower platform used for ladder access was closed when employees were working on the platform. The platform was approximately 20 feet above ground level. This condition exposed employees to a fall hazard of approximately 20 feet.
Recent events (2)
  • · I (O) $2963
  • · Z (S) $5926

1910.147 C06 I

Serious Gravity 10 2 instances 5 exposed
Issued
Aug 9, 2017
Abate by
Sep 29, 2017
Penalty
Initial $9,760 · Current $9,760
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a) KBP Coil Coaters @ 3600 E 44th Ave. Denver, CO:  On or before March 13, 2017, as part of injury/accident prevention responsibilities under its safety program, the employer did not ensure a periodic inspection was conducted of their energy control procedures on machines such as, but not limited to, the Entry Tower roll Accumulator.  On March 13, 2017, at the Paint Line Dept., two employees were seriously injured as a result of uncontrolled hazardous energy while re-threading a coil aluminum sheet through the Entry Tower Roll Accumulator. This condition exposed employees to crushing and caught-in-between hazards as a result of uncontrolled hazardous energy sources present while performing such activity.    Abatement note:  29 CFR 1910.147(c)(6)(ii) requires that the employer certify that periodic inspections of the energy control procedures had been performed.
Recent events (2)
  • · I (S) $9760
  • · Z (S) $9760

1910.147 C07 I

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 9, 2017
Abate by
Sep 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:     (a) KBP Coil Coaters @ 3600 E 44th Ave. Denver, CO:  On or before March 13, 2017, as part of injury/accident prevention responsibilities under its safety program, the employer did not ensure employees were trained in the energy control procedures, as required under the standard, including the safe application, usage and removal of energy control devices.  On March 13, 2017, at the Paint Line Dept., two untrained employees were seriously injured as a result of uncontrolled hazardous energy while re-threading a coil aluminum sheet through the Entry Tower Roll Accumulator. This condition exposed employees to crushing and caught-in-between hazards as a result of uncontrolled hazardous energy sources present while performing such activity.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 9, 2017
Abate by
Sep 29, 2017
Penalty
Initial $5,926 · Current $5,926
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:        (a)   K.B.P. Coil  Corters, Inc. @ 3600 East 44th Avenue, Denver, CO.  80216. On or before March 15, 2017, the employer did not ensure that adequate machine guarding was in place at the entry roller of the coil paint line process, where the coil is fed through to make the initial stitches.  This condition exposed employees to amputation, ingoing nip point, and crushing hazards.
Recent events (2)
  • · I (S) $5926
  • · Z (S) $5926

1910.219 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 9, 2017
Abate by
Aug 29, 2017
Penalty
Initial $5,926 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulleys with parts seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a)  KBP Coil Coaters @ 3600 E 44th Ave. Denver, CO: On or before March 15, 2017, as part of the machine guarding program, the employer did not ensure that a pulley and chain assembly were adequately guarded.  This pulley and chain assembly are located on the work platform on top of the accumulator tower on the paint line dept.  Maintenance employees accessing this work platform were not protected from the hazards associated with this unguarded pulley and chain assembly.  This condition exposed employees to amputation, in-running nip point, and pinch point hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5926

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342181781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.