Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: G&G MEDICAL PRODUCTS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of G&G MEDICAL PRODUCTS LLC in 6 E MAIN ST, WARE, MA 01082 (NAICS 322291). OSHA activity number 342184140.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&G Medical Products LLC for free Get an email when a new federal OSHA severe-injury report for G&G Medical Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
6 E MAIN ST
City
WARE
State
MA
ZIP
01082
Mailing
6 E MAIN ST, WARE, MA 01082
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322291
Employees
300
Ownership type
Private (A)

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 03/20/2017, the employer did not provide effective training to employees about health hazards associated with lead toxicity which includes, but is not limited to: reproductive/developmental toxicity, central nervous system, kidney effects, and acute toxicity effects.  Six bulk samples of removed paint were taken on the second floor where employees were engaged in paint removal and painting activities. The analytical results were received on April 10, 2017 and revealed lead concentrations between 0.17% to 6.5%.
Recent events (2)
  • · I (S) $4527
  • · Z (S) $9054

1926.62 D01 I

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.62(d)(1)(i): The employer did not initially determine if any employee may be exposed to lead at or above the action level.  G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 03/20/2017, the employer had not initially determined if employees, who manually removed lead paint from walls and windows on the second floor, were exposed to lead at or above the action level of 30 ug/m3 calculated as an 8-hour time-weighted average (TWA).
Recent events (2)
  • · I (S) $4527
  • · Z (S) $9054

1926.62 D01 III

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.62(d)(1)(iii):  The employer did not collect personal samples representative of a full shift including at least one sample for each job classification in each work area either for each shift or for the shift with the highest exposure level.  G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 3/20/2017, the employer did not collect personal samples representative of a full shift for employees who manually removed lead paint from walls and windows.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.62 D02 V C

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.62(d)(2)(v)(C): The employer did not provide change areas to employees who performed lead removal work.  G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 3/20/2017, the employer did not provide a change room to employees who manually removed lead paint from walls and windows on the second floor.
Recent events (2)
  • · I (S) $4527
  • · Z (S) $9054

1926.62 D02 V E

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.62(d)(2)(v)(E): The employer did not provide biological monitoring in accordance with paragraph (j)(1)(i) of this section, to consist of blood sampling and analysis for lead and zinc protoporphyrin levels.   G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 3/20/2017, the employer did not provide biological monitoring, consisting of blood sampling and analysis for lead and zinc protoporphyrin levels, to employees who performed manual scraping of lead paint.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.62 F02 I

Serious Gravity 5 3 instances 9 exposed
Issued
Jul 13, 2017
Abate by
Aug 29, 2017
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.62(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m), which covers each employee required by this section to use a respirator.   G&G Medical Products, 6 E Main Street. Ware, MA 01082: On or about 3/20/2017, the employer had not developed and implemented a written respiratory protection program, had not provided medical evaluations and had not provided qualitative or quantitative respirator fit-tests for employees required to wear half face-piece respirators while scraping/removing lead paint from walls and windows on the first and second floor.
Recent events (2)
  • · I (S) $4527
  • · Z (S) $9054

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342184140.