OSHA Inspection: ESTEBAN TORRES CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ESTEBAN TORRES CONSTRUCTION LLC in 2981 GRANTS MILL ROAD, LEEDS, AL 35094 (NAICS 238130). OSHA activity number 342187796.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Esteban Torres Construction LLC — free Get an email when a new federal OSHA severe-injury report for Esteban Torres Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2981 GRANTS MILL ROAD
City
LEEDS
State
AL
ZIP
35094
Mailing
110 COUNTY ROAD 786, JEMISON, AL 35085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 2 exposed
Issued
Jun 30, 2017
Abate by
Aug 7, 2017
Penalty
Initial $305 · Current $305
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) On or about 06/05/2017, the employer failed to submit certification of corrective action for citation 1, item 1 issued on 05/12/2017 with an abatement date of 05/24/2017.  (b) On or about 06/05/2017, the employer failed to submit certification of corrective action for citation 2, item 1a issued on 05/12/2017 with an abatement date of 05/24/2017.  (c) On or about 06/05/2017, the employer failed to submit certification of corrective action for citation 2, item 1b issued on 05/12/2017 with an abatement date of 05/24/2017.
Recent events (1)
  • — Z (O) $305

1926.304 D

Serious Gravity 5 1 instance 2 exposed
Issued
May 12, 2017
Abate by
May 24, 2017
Penalty
Initial $3,259 · Current $3,259
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe:  (a) On or about 3/6/2017 - 2981 Grants Mill Road, Leeds, AL, a Makita, Model 5007F, Serial #1647413Y, circular saw being used to cut/trim sheathing for installing on the roof had the bottom guard shimmed to prevent it from closing.
Recent events (1)
  • — Z (S) $3259

1926.501 B11

Serious Gravity 5 1 instance 3 exposed
Issued
May 12, 2017
Penalty
Initial $2,770 · Current $2,770
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  (a) On or about 3/6/2017 - 2981 Grants Mill Road, Leeds, AL, employees attaching felt to roof sheathing were not protected from falling approximately 11 feet.
Recent events (1)
  • — Z (S) $2770

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
May 12, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On or about 3/6/2017 - 2981 Grants Mill Road, Leeds, AL, the ladder used by employees to access the roof was extended approximately 8 inches above the landing.
Recent events (1)
  • — Z (S) $2173

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
May 12, 2017
Abate by
May 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about 3/6/2017 - 2981 Grants Mill Road, Leeds, AL, an extension cord where strain relief was pulled away and the outer sheath damaged was being used to power a Ryobi, Model CSB134L, 7 1/4 inch circular saw.
Recent events (1)
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 2 exposed
Issued
May 12, 2017
Abate by
May 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) On or about 3/6/2017 - 2981 Grants Mill Road, Leeds, AL, an extension cord with outer sheath damage was used to power a Ryobi, Model CSB134L, 7 1/4 inch circular saw.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342187796.