Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: ROOFTEC OF FLORIDA, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROOFTEC OF FLORIDA, LLC in 38 SURFSIDE DRIVE LOT 40, ORMOND BEACH, FL 32176 (NAICS 238160). OSHA activity number 342190659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rooftec of Florida, LLC — free Get an email when a new federal OSHA severe-injury report for Rooftec of Florida, LLC is published. One employer, no account, unsubscribe in one click.
Site address
38 SURFSIDE DRIVE LOT 40
City
ORMOND BEACH
State
FL
ZIP
32176
Mailing
2909 FAIRCHILD COURT, TALLAHASSEE, FL 32309
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets:  a. On or about March 21, 2017, the employee handing materials up to the employees on the roof was not wearing a hard hat and was being exposed to head injuries.
Recent events (2)
  • — I (S) $2173
  • — Z (S) $2173

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a. On or about March 21, 2017, employees using nail guns to install plywood were not wearing eye protection, exposing themselves to being struck by flying debris or nails.
Recent events (2)
  • — I (S) $2173
  • — Z (S) $2173

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
Jun 8, 2017
Abate by
Jul 26, 2017
Penalty
Initial $10,140 · Current $7,677 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a. Employees installing plywood at elevations of 6 feet or more above the ground are not being protected from fall hazards by a fall protection system:    The employer fails to assure effective protection against falls as required by the standard, as demonstrated on Mar 21, 2017, when employees installing plywood on a 5:12 pitch roof at 38 Surfside Drive, Ormond Beach, FL 32176, were exposed to an 9 feet fall hazard above the ground in that they did not have a fall protection system installed.    Roofing R US Systems, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1167770, citation number 01, item number 001 and was affirmed as a final order on February 24, 2016, with respect to a workplace located at 612 Robin Lane, Kissimmee, FL 34759.    Roofing R US Systems, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 1137457, citation number 01, item number 001 and was affirmed as a final order on August 24, 2016, with respect to a workplace located at 9008 Harney Road, Tampa, FL 33637.
Recent events (2)
  • — I (R) $7677
  • — Z (R) $10140

1926.1053 B01

Repeat Gravity 10 1 instance 2 exposed
Issued
Jun 8, 2017
Penalty
Initial $10,140 · Current $7,677 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a. On or about March 21, 2017, front of home, employees were using a ladder that was extended 14 inches above the landing and was not secured to prevent accidental displacement.  The employees were being exposed to a 9 feet fall hazard.    Roofing R US Systems, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1167770, citation number 01, item number 002 and was affirmed as a final order on February 24, 2017, with respect to a workplace located at 612 Robin Lane, Kissimmee, FL 34759.
Recent events (2)
  • — I (R) $7677
  • — Z (R) $10140

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342190659.