OSHA Inspection: VINTON STEEL, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VINTON STEEL, LLC in 8001 BORDER STEEL, VINTON, TX 79821 (NAICS 331110). OSHA activity number 342194859.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vinton Steel, LLC for free Get an email when a new federal OSHA severe-injury report for Vinton Steel, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VINTON STEEL, LLC
Site address
8001 BORDER STEEL
City
VINTON
State
TX
ZIP
79821
Mailing
8001 BORDER STEEL, VINTON, TX 79821
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
10
Ownership type
Private (A)

3 citations on file for this inspection.

1910.28 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Jun 9, 2017
Abate by
Jul 14, 2017
Penalty
Initial $12,675 · Current $7,600 Reduced
29 CFR 1910.28(b)(1)(i): (1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling:      COLD SHEAR AREA- On or about March 15, 2017 the employer did not ensure that employees were provided with and/or required to use fall protection. This condition exposed employees to fall hazards of 4 feet or more.
Recent events (2)
  • · I (O) $7600
  • · Z (S) $12675

1910.30 A01

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jun 9, 2017
Abate by
Aug 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(1): Before any employee is exposed to a fall hazard, the employer must provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart.     On or about March 15, 2017 the employer did not ensure that adequate fall protection training was provided and implemented. This condition exposed employees to fall hazards of 4 feet or more.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.176 B

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 9, 2017
Abate by
Jun 26, 2017
Penalty
Initial $12,675 · Current $7,600 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    COLD SHEAR AREA- On or about March 15, 2017 the employer did not ensure that loaded material on a transfer cart was stable and secured against sliding and collapse: This condition exposed employees to fall hazards of 4 feet or more.
Recent events (2)
  • · I (S) $7600
  • · Z (S) $12675

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342194859.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.