On , OSHA opened a planned health inspection of REED MILLWORK, LLC in 13103 LOOKOUT RIDGE, SAN ANTONIO, TX 78233 (NAICS 337110). OSHA activity number 342194867.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reed Millwork, LLC for free Get an email when a new federal OSHA severe-injury report for Reed Millwork, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
REED MILLWORK, LLC
Site address
13103 LOOKOUT RIDGE
City
SAN ANTONIO
State
TX
ZIP
78233
Mailing
13103 LOOKOUT RIDGE, SAN ANTONIO, TX 78233
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
4
Ownership type
Private (A)

4 citations on file for this inspection.

1910.212 B

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 14, 2017
Abate by
May 1, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:   a) Warehouse, west side: On March 23, 2017, and times prior thereto, employee(s) were exposed to struck-by hazards from the use of a DeWalt Miter Saw (Model DW705, SN: 204932) which was used to cut wood and particle board materials and was not anchored to a fixed location.   b) Warehouse, east side: On March 23, 2017, and times prior thereto, employee(s) were exposed to struck-by hazards from the use of a DeWalt Miter Saw (Model DW718, SN: 972250 20062749) which was used to cut wood and particle board materials and was not anchored to a fixed location.
Recent events (2)
  • · I (S) $1303.8
  • · Z (S) $2173

1910.334 A02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 14, 2017
Abate by
May 1, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  Warehouse, east side: On or about March 23, 2017, employee(s) performing sanding processes on wood and particle board were exposed to electrical hazards from the use of a Dewalt Random Orbit Palm Sander (Model DW421, SN: 243835) which had a damaged electrical cord.
Recent events (2)
  • · I (S) $978
  • · Z (S) $1630

1910.22 B

Other-than-serious 2 instances 3 exposed
Issued
Apr 14, 2017
Abate by
May 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface:  a) Storage area: On or about March 23, 2017, employees were exposed to a struck-by hazard from material which was stored in an elevated space that was not rated for an approved load capacity or for storage purposes.   b) Warehouse: On or about March 23, 2017, employees were exposed to a struck-by hazard from material which was stored in a space above the restroom that was not rated for an approved load capacity or for storage purposes.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 3 exposed
Issued
Apr 14, 2017
Abate by
May 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): Working space about electric equipment rated 600 volts, nominal, or less was not provided with the minimal depth in the direction of access to live parts as indicated in Table S-1:   Warehouse, east side : On or about March 23, 2017, employee(s) were exposed to a fire hazard from a blocked electrical panel, which was obstructed by wood frames, boxes, and storage cabinets.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342194867.