OSHA Inspection: TEXAS DIP MOLDING & COATING INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of TEXAS DIP MOLDING & COATING INC. in 12778 O'CONNOR RD, SAN ANTONIO, TX 78233 (NAICS 326199). OSHA activity number 342195815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas DIP Molding & Coating INC. — free Get an email when a new federal OSHA severe-injury report for Texas DIP Molding & Coating INC. is published. One employer, no account, unsubscribe in one click.
Site address
12778 O'CONNOR RD
City
SAN ANTONIO
State
TX
ZIP
78233
Mailing
12778 O'CONNOR RD, SAN ANTONIO, TX 78233
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 30, 2017
Abate by
Jul 17, 2017
Penalty
Initial $3,622 · Current $1,700 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    Production Area: On or about March 23, 2017, and times prior thereto, employees were exposed to hot surface hazards while working in close quarters near exposed heated racks on the Texas #1 machine, and adequate personal protective equipment to prevent dermal burns was not provided.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3622

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 30, 2017
Penalty
Initial $2,173 · Current $1,000 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Storage Room: On or about March 23, 2017, and times prior thereto, employees were exposed to struck-by and caught-in hazards from the use of a Porter Cable Drill Press (Model: PCXB620DP, SN: 008657) which was used to drill lead bars and was not anchored to a fixed location.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2173

1910.1025 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 30, 2017
Abate by
Jul 17, 2017
Penalty
Initial $2,897 · Current $0 Reduced

Hazardous substances 1591BWPB

29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:    Storage Room: On or about March 28, 2017, employees were exposed to health hazards from the accumulation of lead on drill press surfaces in the storage room which was accessed and used by employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2897

1910.1200 E01

Serious Gravity 5 1 instance 12 exposed
Issued
Jun 30, 2017
Abate by
Jul 26, 2017
Penalty
Initial $2,897 · Current $1,300 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    Warehouse: On or about March 23, 2017, and times prior there to, the employer did not implement or maintain an effective written Hazard Communication Program to train and inform employee(s) and temporary employees who handle, use, transport or are potentially exposed to hazards from chemicals and other hazardous materials, such as but not limited to, Silicone protective coatings (Solvent Naphtha), Vinyl Coatings,  Xylene, chemical ink solvent (Naphtha, Cyclohexanone), Compressed gases (Nitrogen), and Lead.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2897

1910.303 G01 I A

Other-than-serious 1 instance 2 exposed
Issued
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): Working space about electric equipment rated 600 volts, nominal, or less was not provided with the minimal depth in the direction of access to live parts as indicated in Table S-1:  Production Area, Rear: On or about March 23, 2017, employee(s) were exposed to a fire hazard from a blocked electrical panel, which as obstructed by the storage of insulation boards.