Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LYN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LYN CONSTRUCTION, INC. in 312 23RD AVENUE, OTTAWA, IL 61350 (NAICS 238160). OSHA activity number 342196334.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LYN Construction, INC. for free Get an email when a new federal OSHA severe-injury report for LYN Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
312 23RD AVENUE
City
OTTAWA
State
IL
ZIP
61350
Mailing
606 GRAND AVE, AURORA, IL 60506
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 3 instances 5 exposed
Issued
Jul 10, 2017
Penalty
Initial $2,173 · Current $1,200 Reduced
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.     a. On or about March 23, 2017 - at the above addressed jobsite, employees were required to access / egress a residential roof using a ladder placed in close proximity to the electrical utility service drop. Employees were thereby exposed to electrical burns / shock.    b. Employees were observed working above or around the electrical utility service drop at the time of inspection. Employees were thereby exposed to electrical burns / shock.    No abatement is required for this item.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2173

1926.501 B13

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 10, 2017
Penalty
Initial $1,630 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.     On or about March 23, 2017, employees performing residential roofing installation operations at a residential property were exposed to a 8' foot fall hazard when the employer failed to ensure fall protection was utilized.      No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1630

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 10, 2017
Penalty
Initial $1,630 · Current $1,800
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:     a.  On or about March 23, 2017 - at the above addressed jobsite, employees were required to work from a ladder that did not extend three (3) feet above the roof's eve during roofing material removal / installation operations at heights up to eight (8) feet. Employees ascending / descending the ladder were thereby exposed to fall hazards.     No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $1630

1926.1053 B05 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 10, 2017
Penalty
Initial $1,793 · Current $0 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):    a.  On or about March 23, 2017 - at the above addressed jobsite, employees were required to work from ladders during roofing material removal / installation operations while ascending / descending a ladder placed at an unsafe angle. Employees were thereby exposed to falls of up to eight (8) feet.      There is no abatement certification of documentation required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1793

1926.1053 B06

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement:  a.  On or about March 23, 2017 - at the above addressed jobsite, employees were required to work from ladders placed on unstable surfaces during roofing material removal / installation operations approximately eight (8) feet from eve to the ground. Employees ascending / descending the ladder were thereby exposed to fall hazards.    There is no abatement certification of documentation required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.20 B02

Other-than-serious 3 instances 3 exposed
Issued
Jul 10, 2017
Abate by
Aug 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a. On or about March 23, 2017, at the above addressed jobsite, safety inspections were not made by persons capable of identifying and correcting those hazards which could result in employee injuries. Employees were thereby exposed to fall / electrical / struck-by hazards at this jobsite.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View LYN Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342196334.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.