PONCHA SPRINGS, CO —
OSHA Inspection: PURSELL MANUFACTURING CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PURSELL MANUFACTURING CORP in 135 PAHLONE PKWY, PONCHA SPRINGS, CO 81242 (NAICS 339999). OSHA activity number 342196441.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PURSELL MANUFACTURING CORP
- Site address
- 135 PAHLONE PKWY
- City
- PONCHA SPRINGS
- State
- CO
- ZIP
- 81242
- Mailing
- PO BOX 248, PONCHA SPRINGS, CO 81242
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 11
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.176 B
- Issued
- May 2, 2017
- Penalty
- Initial $1,570 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) Warehouse 155: On or about March 21, 2017, and at times prior, workers were exposed to struck-by hazards while working near a second level pallet of material weighing 675 pounds that was leaning approximately 7.5 degrees toward an aisle. Abatement Note: The employer corrected this condition during the inspection. Applied Quick-Fix reduction.
Recent events (2)
- — I (S) $0
- — Z (S) $1570
1910.305 G01 IV
- Issued
- May 2, 2017
- Penalty
- Initial $1,847 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) As a substitute for the fixed wiring of a structure; (C) Where run through doorways, windows, or similar openings; (D) Where attached to building surfaces: a) Production Bldg 135: On or about March 21, 2017, and at times prior, workers were exposed to electrical hazards where UF-B Sunlight Resistant 12/2 conductor was used as flexible cord with hazards including but not limited to: 1) Conductor fitted with a cord end (designed for direct box or panel connection). 2) Conductor not protected by conduit or raceway. 3) Rolling door and side hinged door closed on conductor. 4) Conductor physically attached to building structure with wire ties. Abatement Note: The employer corrected this condition during the inspection.
Recent events (2)
- — I (S) $1000
- — Z (S) $1847
1910.305 G02 III
- Issued
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Behind Flock Mixer: On or about March 21, 2017, and at times prior, workers were exposed to electrical hazards where the outer cover was pulled from a flexible cord end fitting which allowed direct pull to terminal screws. Abatement Note: The employer corrected this condition during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- May 2, 2017
- Abate by
- Jun 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) On or about March 21, 2017, and at times prior, the employer did not prepare a certificate within the preceding three years to affirm that powered industrial truck operators retained proficiency with assigned tasks. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pursell Manufacturing Corp
View Pursell Manufacturing Corp's full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342196441.