WASHINGTON, DC —
OSHA Inspection: GARNICA CONTRACTORS, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GARNICA CONTRACTORS, LLC in 1720 NEW JERSEY AVE., NW, WASHINGTON, DC 20005 (NAICS 238350). OSHA activity number 342196748.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARNICA CONTRACTORS, LLC
- Site address
- 1720 NEW JERSEY AVE., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20005
- Mailing
- 11431 CHERRY HILL RD. APT. 301, BELTSVILLE, MD 20704
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.1052 B02
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $3,259 · Current $3,259
General-duty citation text
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area: a) Landings, Stairway No. 1 On or about March 21, 2017, the 7 foot 2 inch by 3 foot 9 inch pan stair landings in a stairway, which were not under construction and provided for temporary use, were not fitted with temporary landings thereby exposing workers to a potential 10 ft. fall hazard. b) Landings, Stairway No. 2 On or about March 21, 2017, the 7 foot 2 inch by 3 foot 9 inch pan stair landings in a stairway, which were not under construction and provided for temporary use, were not fitted with temporary landings thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $3259
1926.1052 C01 I
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $3,259 · Current $3,259
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Stairway No. 1 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with handrails thereby exposing workers to a potential 10 ft. fall hazard. b) Stairway No. 2 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with handrails thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $3259
1926.1052 C01 II
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Stairway No. 1 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with stairrails on all open sides thereby exposing workers to a potential 10 ft. fall hazard. b) Stairway No. 2 On or about March 21, 2017, flights of metal stairs, having at least nine risers and which ran between four floors of a building under construction, were not provided with stairrails on all open sides thereby exposing workers to a potential 10 ft. fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.451 B03
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a) Atrium On or about March 21, 2017, two workers installing sheathing and insulation boards from the 12 inch wide platform of a pump jack scaffold were exposed to a 40 foot fall for their work platform was located 21 inches (horizontally) away from the wall surface they were working upon. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3803
1926.451 G01 I
- Issued
- Jun 20, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Atrium On or about March 21, 2017, four workers installing sheathing and insulation boards from the platform of a pump jack scaffold were not provided with personal fall protection and were exposed to a 40 foot fall. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.