OSHA Inspection: BOLITA PALLET REPAIR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOLITA PALLET REPAIR, INC. in 2013 W. FERDINAND STREET, CHICAGO, IL 60612 (NAICS 321920). OSHA activity number 342200953.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bolita Pallet Repair, INC. for free Get an email when a new federal OSHA severe-injury report for Bolita Pallet Repair, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2013 W. FERDINAND STREET
City
CHICAGO
State
IL
ZIP
60612
Mailing
4429 W. 79TH PLACE, CHICAGO, IL 60652
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training, and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup, or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      a) Pallet Shop- On March 24, 2017, the employer did not develop, document, or utilize an energy control program (lockout/tagout program), that included an energy control procedure for employees to follow, training to ensure that all required elements of the procedure were understood by employees, including safe application, usage, and removal of the energy isolating controls, and periodic inspections to ensure that employees were protected from injuries caused by the unexpected energizing of equipment or release of stored energy . Employees performed servicing and maintenance on equipment, such as repairing or replacing small parts, including bearings, and blades on the pallet disassembler.
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):       a) Facility Wide- On March 24, 2017, the employer did not ensure that all employees who operate the powered industrial vehicles demonstrated their competency through training, evaluation, and certification of their driving capabilities.
Recent events (2)
  • · I (S) $978
  • · Z (S) $1630

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a) Pallet Shop- On March 24, 2017, the employer did not ensure that a guard was used to cover all unused portions of the saw blade and the rotating pulley on the pallet disassembler.
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:       a) Pallet Shop- On March 24, 2017, the employer did not ensure that all outlet boxes were equipped with a cover or faceplate.
Recent events (2)
  • · I (S) $978
  • · Z (S) $1630

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Jun 8, 2017
Abate by
Jul 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:     a) Pallet Shop- On March 24, 2017, the employer did not ensure that extension cords were not used as a substitute for fixed wiring.  Extension cords were used to supply power to overhead lighting.