Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.C. SPECIALTY FABRICATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of R.C. SPECIALTY FABRICATION, INC. in 96 COMMERCIAL STREET, LEWISTON, ME 04240 (NAICS 332999). OSHA activity number 342202843.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.C. Specialty Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for R.C. Specialty Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
96 COMMERCIAL STREET
City
LEWISTON
State
ME
ZIP
04240
Mailing
96 COMMERCIAL STREET, LEWISTON, ME 04240
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 4 instances 1 exposed
Issued
May 3, 2017
Abate by
Jun 20, 2017
Penalty
Initial $2,716 · Current $1,901 Reduced
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:  Spray Area - An exhaust fan motor, overhead fluorescent lights, an electrical outlet and a propane heater all located outside of but within 20 feet of the spray area did not conform to the provisions of subpart S of this part for Class I, Division 2 hazardous locations.
Recent events (2)
  • — I (S) $1901.2
  • — Z (S) $2716

1910.134 C01

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2017
Abate by
May 30, 2017
Penalty
Initial $2,173 · Current $1,521 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    Facility - The written respiratory protection program did not include all the provisions in 29 CFR 1910.134(c)(1)(I)-(ix), and was not fully implemented.
Recent events (2)
  • — I (S) $1521.1
  • — Z (S) $2173

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2017
Abate by
May 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Facility - The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before it was required for use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2017
Abate by
May 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator and at least annually thereafter:  Facility - Employee using a half-face cartridge respirator was not fit tested prior to initial use nor annually thereafter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2017
Abate by
May 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    Facility - Respirator was not stored to protect from contamination; it was found uncovered,  on the wall near a grinding table/work bench.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 5 2 instances 3 exposed
Issued
May 3, 2017
Abate by
May 9, 2017
Penalty
Initial $2,716 · Current $1,901 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  Facility - The Yale fork truck had an inoperable parking brake and back-up alarm and had not been taken out of service.
Recent events (2)
  • — I (S) $1901.2
  • — Z (S) $2716

1910.334 A02 II

Other-than-serious 2 instances 2 exposed
Issued
May 3, 2017
Abate by
May 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:  Shop - Grounding pins were missing from two extension cords that were not removed from service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View R.C. Specialty Fabrication, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342202843.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.