OSHA Inspection: SUNRISE HITEK GROUP LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNRISE HITEK GROUP LLC in 5915 N NORTHWEST HWY, CHICAGO, IL 60631 (NAICS 323111). OSHA activity number 342203015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrise Hitek Group LLC — free Get an email when a new federal OSHA severe-injury report for Sunrise Hitek Group LLC is published. One employer, no account, unsubscribe in one click.
Site address
5915 N NORTHWEST HWY
City
CHICAGO
State
IL
ZIP
60631
Mailing
5915 N NORTHWEST HWY, CHICAGO, IL 60631
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
16
Ownership type
A

6 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 1 instance 9 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $2,897 · Current $1,500 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:    a) Shipping Receiving Area- On March 24, 2017, the employer failed to ensure that all powered industrial trucks with modifications and additions, which affect the capacity, were performed with the written approval of the manufacturer and all capacity plates were changed accordingly.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2897

1910.178 A05

Serious Gravity 5 1 instance 9 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  a) Shipping Receiving Area- On March 24, 2017, the employer failed to ensure that all powered industrial trucks equipped with front-end attachments other than the factory installed forks, such as the 72 inch Vestil Fork Extension Caps on the Yale Forklift, were provided markings to identify the attachments and the approximate capacity of the attachment combination and truck with the load laterally centered.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $3,622 · Current $1,800 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) Shipping Receiving Area- On March 24, 2017, the employer failed to ensure that each powered industrial truck operator was competent to operate powered industrial trucks, such as the Yale Forklift, safely as demonstrated by the successful completion of operator training and evaluation.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3622

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 9, 2017
Penalty
Initial $3,622 · Current $1,800 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Cutting Room-  On or about March 1, 2017, the employer failed to ensure that all areas where hazards created by the point of operation were guarded on machinery, such as the Skilsaw 10" Table Saw, to prevent injury to employees during the operation of the machine.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3622

1910.303 B02

Serious Gravity 5 1 instance 9 exposed
Issued
May 9, 2017
Abate by
Jun 5, 2017
Penalty
Initial $4,346 · Current $2,175 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Bindery Area- On March 24, 2017, the employer failed to ensure that electrical equipment, such as the multiple outlet relocatable power taps in the Bindery area, were being used only to power audiovisual equipment as permitted under its listing and labeling.  The multiple outlet relocatable power taps were used to power additional multiple outlet relocatable power taps, the Automatic Paper Folder, the Duplo Booklet Maker and other extension cords.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2175
  • — Z (S) $4346

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
May 9, 2017
Penalty
Initial $1,847 · Current $925 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    a) Bindery Area- On March 24, 2017, the employer failed to ensure that electrical equipment, such as the cord running to the Automatic Paper Folder and the orange extension cord near that machine, were provided with strain relief so that tension would not be transmitted to joints.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $925
  • — Z (S) $1847

View Sunrise Hitek Group LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342203015.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.