Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CREATIVE CLOSETS UNLIMITED, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CREATIVE CLOSETS UNLIMITED, INC. in 16 AVENUE E, HOPKINTON, MA 01748 (NAICS 337215). OSHA activity number 342207263.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Creative Closets Unlimited, INC. — free Get an email when a new federal OSHA severe-injury report for Creative Closets Unlimited, INC. is published. One employer, no account, unsubscribe in one click.
Site address
16 AVENUE E
City
HOPKINTON
State
MA
ZIP
01748
Mailing
16 AVENUE E, HOPKINTON, MA 01748
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
105
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 7 instances 105 exposed
Issued
May 15, 2017
Abate by
Jan 1, 2018
Penalty
Initial $11,408 · Current $8,000 Reduced

Hazardous substances W103

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards from dust collectors being located inside a building:    (a) Location - 16 Avenue E, Hopkinton, MA:    On or about 3/29/2017, enclosureless dust collectors located indoors throughout the production facility are designed to operate in excess of 5,000 cubic feet per minute, are located in close proximity to means of egress, other enclosureless dust collectors, and areas routinely occupied by employees, and the dust that is collected is not removed at least daily.     The dust was tested and determined to be a dust explosion class St 1 explosive dust by the Salt Lake City Technical Center.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $11408

1910.22 A02

Serious Gravity 5 2 instances 105 exposed
Issued
May 15, 2017
Penalty
Initial $0 · Current $0

Hazardous substances W103

29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean condition:  (a) Location - 16 Avenue E, Hopkinton, MA:  On or about 3/29/2017, an excessive amount of combustible wood dust was allowed to accumulate on the floor in and around "Closet 2" and in "Closet 1".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 C02 VII

Serious Gravity 5 1 instance 17 exposed
Issued
May 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(c)(2)(vii):  Power-operated industrial trucks designated as DY, EE, or EX were not used in atmospheres in which combustible dust is not normally in suspension in the air  by normal operation of equipment or apparatus but where deposits or accumulations of such dust could be ignited by arcs or sparks originating in the truck:  (a) Location 16 Avenue E, Hopkinton, MA:  On or about 3/29/2017, forklifts designated type LP were operated in areas of the facility where combustible wood dust was allowed to accumulate in excess.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 B

Serious Gravity 5 3 instances 105 exposed
Issued
May 15, 2017
Abate by
Jan 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.307(b): Areas designated as hazardous (classified) locations under the Class and Zone system and areas designated under the Class and Division system established after August 13, 2007 were not properly documented:    (a) Location - 16 Avenue E, Hopkinton, MA:    On or about 3/29/2017, designated hazardous locations associated with the operation of enclosureless wood dust collectors were not documented.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C

Serious Gravity 5 3 instances 105 exposed
Issued
May 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  (a) Location - 16 Avenue E, Hopkinton, MA:  On or about 3/29/2017, outlet boxes installed in areas designated as Class II Division 2 hazardous locations were not intrinsically safe, approved for installation in hazardous locations, or otherwise rendered safe for installation in hazardous locations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 17 exposed
Issued
May 15, 2017
Abate by
Jun 19, 2017
Penalty
Initial $8,149 · Current $6,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Location - 16 Avenue E, Hopkinton, MA:    On or about 3/29/2017, a program consisting of procedures, training, and periodic inspection has not been developed to protect employees from hazards associated with the unexpected energization or release of stored energy while performing maintenance and/or service on equipment and/or machinery.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $8149

1910.242 B

Serious Gravity 1 1 instance 17 exposed
Issued
May 15, 2017
Abate by
Jun 19, 2017
Penalty
Initial $4,889 · Current $3,000 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Location - 16 Avenue E, Hopkinton, MA:    On or about 3/29/2017, compressed air used for cleaning wood dust off of material in process was supplied at over 100 p.s.i.g.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4889

1910.157 C04

Other-than-serious 1 instance 17 exposed
Issued
May 15, 2017
Penalty
Initial $914 · Current $500 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places at all times except during use:    (a) Location - 16 Avenue E, Hopkinton, MA:    On or about 3/29/2017, the portable fire extinguisher by the loading dock was not mounted.
Recent events (2)
  • — I (O) $500
  • — Z (O) $914

1910.157 G01

Other-than-serious 1 instance 17 exposed
Issued
May 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:  (a) Location - 16 Avenue E, Hopkinton, MA:  On or about 3/29/2017, training on the general principles of fire extinguisher use and the hazards involved with fighting incipient stage fires was not provided to employees expected to fight fires.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Creative Closets Unlimited, INC.'s full OSHA safety record →