WILKES BARRE, PA ·
OSHA Inspection: QUALITY & MORE CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUALITY & MORE CONSTRUCTION LLC in HERITAGE POINT APARTMENTS 133 DANA ST., WILKES BARRE, PA 18702 (NAICS 238170). OSHA activity number 342210036.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY & MORE CONSTRUCTION LLC
- Site address
- HERITAGE POINT APARTMENTS 133 DANA ST.
- City
- WILKES BARRE
- State
- PA
- ZIP
- 18702
- Mailing
- 60 LIBERTY ST., WEST ORANGE, NJ 07052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.502 D16 III
- Issued
- May 9, 2017
- Abate by
- May 19, 2017
- Penalty
- Initial $1,630 · Current $800 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: Personal fall arrest systems for use by employees on pump jack scaffolds were not rigged such that an employee could not free fall more than 6 feet (measured at 10.5 feet) nor contact any lower level, as observed on or about March 30, 2017. Abatement Certification Required.
Recent events (3)
- · F (S) $800
- · C (S) $1630
- · Z (S) $1630
1926.502 D15
- Issued
- May 9, 2017
- Abate by
- May 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: Anchorage for personal fall arrest systems used by employees on pump jack scaffolds was to the side rails of ladders used as work tables on the scaffolds, as observed on or about March 30, 2017. Abatement Certification Required.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1926.501 B01
- Issued
- May 9, 2017
- Abate by
- May 19, 2017
- Penalty
- Initial $2,173 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: Employees were working on the roof of the building, installing vinyl siding at a height of 10 feet above the ground level without fall protection, as observed on or about March 30, 2017. Abatement Certification Required.
Recent events (3)
- · F (S) $1100
- · C (S) $2173
- · Z (S) $2173
1926.1053 B01
- Issued
- May 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: Ladders used to access the roof of the building did not extend at least 3 feet above the upper landing surface (roof), as observed on or about March 30, 2017. Abatement Observed During Inspection.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1926.503 A01
- Issued
- May 9, 2017
- Abate by
- Jun 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: The employer did not provide a training program for each employee potentially exposed to fall hazards and the correct procedures for erecting, maintaining and inspecting fall protection systems, on or about March 30, 2017. Abatement Certification Required.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1926.404 F06
- Issued
- May 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Building #3 Heritage Point Apartments, Wilkes-Barre, PA: The ground prong on the flexible cord used to supply power to a portable circular saw was missing, as observed on or about March 30, 2017. Abatement Observed During Inspection.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238170)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342210036.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.