ALLENTOWN, PA —
OSHA Inspection: ALAN KUNSMAN ROOFING & SIDING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALAN KUNSMAN ROOFING & SIDING, INC. in 2024 LEHIGH STREET, ALLENTOWN, PA 18103 (NAICS 238160). OSHA activity number 342210341.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALAN KUNSMAN ROOFING & SIDING, INC.
- Site address
- 2024 LEHIGH STREET
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18103
- Mailing
- 203 WASHINGTON ST., FREEMANSBURG, PA 18017
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 80
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.502 F01
- Issued
- Apr 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) Alan Kunsman Roofing & Siding, Inc., Northwest side, upper roof - On or about March 30, 2017, portions of the warning lines were laying on the roof surface and were not erected on all sides of the roof work area. b) Alan Kunsman Roofing & Siding, Inc., Southeast side, lower roof - On or about March 30, 2017, portions of the warning lines were laying on the roof surface and were not erected on all sides of the roof work area.
Recent events (1)
- — Z (O) $0
1926.502 F01 I
- Issued
- Apr 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: a) Alan Kunsman Roofing & Siding, Inc., Southeast side, lower roof - On or about March 30, 2017, portions of the warning lines were erected less than 6 feet from the roof edge.
Recent events (1)
- — Z (O) $0
1926.502 F02 II
- Issued
- Apr 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. a) Alan Kunsman Roofing & Siding, Inc., Northwest side, upper roof - On or about March 30, 2017, portions of the warning lines were not supported in such a way that the lowest point was not less than 34 inches from the roof surface. b) Alan Kunsman Roofing & Siding, Inc., Southeast side, lower roof - On or about March 30, 2017, portions of the warning lines were not supported in such a way that the lowest point was not less than 34 inches from the roof surface.
Recent events (1)
- — Z (O) $0
More inspections at Alan Kunsman Roofing & Siding, INC.
View Alan Kunsman Roofing & Siding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342210341.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.