OSHA Inspection: ADVANCED AIR OF WEST PALM BEACH INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ADVANCED AIR OF WEST PALM BEACH INC. in 6461 GARDEN ROAD STE.102, RIVIERA BEACH, FL 33403 (NAICS 332710). OSHA activity number 342214525.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced AIR of West Palm Beach INC. — free Get an email when a new federal OSHA severe-injury report for Advanced AIR of West Palm Beach INC. is published. One employer, no account, unsubscribe in one click.
Site address
6461 GARDEN ROAD STE.102
City
RIVIERA BEACH
State
FL
ZIP
33403
Mailing
6461 GARDEN ROAD, RIVIERA BEACH, FL 33403
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 4 instances 10 exposed
Issued
Apr 24, 2017
Abate by
May 25, 2017
Penalty
Initial $4,310 · Current $2,586 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded:  Instances:  a) On or about 3/31/17, at the above address jobsite second production room, the  grinding machine tool & cutter (SN 315AQ15Z-0062) was not guarded at the point of operation.   b) On or about 3/31/17, at the above address jobsite at the entrance of the second production room, the Hardinge lathe was not guarded at the point of operation.  c) On or about 3/31/17, at the above address jobsite at the rear of the second production room, the Hardinge lathe was not guarded at the point of operation.  d) On or about 3/31/17, at the above address jobsite at the exterior of the building, the HW Acheon Machinery lathe was not guarded at the point of operation.
Recent events (2)
  • — I (S) $2586
  • — Z (S) $4310

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2017
Abate by
May 18, 2017
Penalty
Initial $5,387 · Current $3,232 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  Instances: 1) On or about 3/31/2017, at the above address jobsite, the employer had not replaced the cover for live parts on the CNC machine (LB1511) while its was in use by the operator at the second production room.   2) On or about 3/31/2017, at the above address jobsite, the electrical receptacle outlet had live parts exposed and a cover was not installed properly while it was in use at the second production room.
Recent events (2)
  • — I (S) $3232.2
  • — Z (S) $5387

1910.305 G01 IV

Serious Gravity 5 2 instances 10 exposed
Issued
Apr 24, 2017
Abate by
May 25, 2017
Penalty
Initial $4,310 · Current $2,586 Reduced
29 CFR 1910.305(g)(1)(iv):  Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:  Instances:  a) On or about 3/31/2017, at the above address jobsite, the employer had used extension cords to power the lighting in the machine shop.  b) On or about 3/31/2017, at the above address jobsite, the employer had extension cords used to power the lighting in the second production room.    -
Recent events (2)
  • — I (S) $2586
  • — Z (S) $4310

1910.37 B06

Other-than-serious 1 instance 5 exposed
Issued
Apr 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  On or about 3/31/2017, at the above address jobsite, the exit sign in the second production room was not illuminated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F08

Other-than-serious 1 instance 2 exposed
Issued
Apr 24, 2017
Abate by
Jun 9, 2017
Penalty
Initial $605 · Current $363 Reduced
29 CFR 1910.1200(f)(8): The employer did not ensure that portable containers into which hazardous chemicals were  transferred from labeled containers and which were not intended for the immediate use of the person doing the transfer, were properly labeled:  On or about 3/31/17, at the above address jobsite, the employer had not labeled a plastic spray bottle (portable container) that contained Astro-Cut A. The spray bottle was used by several employees while working in the machine shop.
Recent events (2)
  • — I (O) $363
  • — Z (O) $605

View Advanced AIR of West Palm Beach INC.'s full OSHA safety record →