SCOTT, LA —
OSHA Inspection: BEGNEAUD MANUFACTURING INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BEGNEAUD MANUFACTURING INCORPORATED in 306 EAST AMEDEE PO BOX 62949, SCOTT, LA 70583 (NAICS 332312). OSHA activity number 342215720.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEGNEAUD MANUFACTURING INCORPORATED
- Site address
- 306 EAST AMEDEE PO BOX 62949
- City
- SCOTT
- State
- LA
- ZIP
- 70583
- Mailing
- PO BOX 62949, LAFAYETTE, LA 70596
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 27
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jul 7, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $3,879 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 3/29/17 in the Press Brake and Weld Fabrication Departments; the employer allowed employees to perform preventative maintenance (PM) on the V130 press brakes and no machine-specific lockout procedures were developed and used during the PM; thus exposing employees to potential laceration/amputation hazards and injuries.
Recent events (2)
- — I (S) $0
- — Z (S) $3879
1910.147 C06 I
- Issued
- Jul 7, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On or about 3/29/17 in the Press Brake and Weld Fabrication Departments; the employer allowed employees to perform preventative maintenance (PM) on the V130 press brakes and no periodic inspection of the energy control procedure had been conducted; thus exposing employees to potential laceration/amputation hazards and injuries.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jul 7, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. On or about 3/29/17 in the Press Brake and Weld Fabrication Departments; the employer allowed employees to perform preventative maintenance (PM) on the V130 press brakes and the employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees; thus exposing employees to potential laceration/amputation hazards and injuries.