BALTIMORE, MD ·
OSHA Inspection: FIRST MARINE CONTRACTORS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FIRST MARINE CONTRACTORS, INC. in 2600 BROENING HIGHWAY DUNDALK MARINE TERMINAL FMC SHOP, BALTIMORE, MD 21224 (NAICS 811111). OSHA activity number 342216801.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIRST MARINE CONTRACTORS, INC.
- Site address
- 2600 BROENING HIGHWAY DUNDALK MARINE TERMINAL FMC SHOP
- City
- BALTIMORE
- State
- MD
- ZIP
- 21224
- Mailing
- 2200 BROENING HIGHWAY SUITE 100, BALTIMORE, MD 21224
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1917.122 C
- Issued
- Jun 19, 2017
- Abate by
- Aug 4, 2017
- Penalty
- Initial $4,753 · Current $0 Reduced
General-duty citation text
29 CFR 1917.122(c): Exits were not readily accessible and sufficient in number to provide employees with a convenient means of escape in emergencies: a) FMC Garage, NW Corner - Emergency exit door was provided with a thumb latch device that could restrict egress in the event of an emergency, on or about 03/29/2017. b) FMC Garage, SW Corner - Emergency exit door was provided with a thumb latch device that could restrict egress in the event of an emergency, on or about 03/29/2017. c) FMC Garage, NE Corner - Emergency exit door was provided with a thumb latch device that could restrict egress in the event of an emergency, on or about 03/29/2017. d) FMC Garage, SE Corner - Emergency exit door was provided with a thumb latch device that could restrict egress in the event of an emergency, on or about 03/29/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · F (S) $0
- · C (S) $4753
- · Z (S) $4753
1917.152 D01 VII
- Issued
- Jun 19, 2017
- Abate by
- Jun 23, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1917.152(d)(1)(vii): Compressed gas cylinders were not secured in an upright position except when hoisted or carried: a) FMC Garage - (2) 100 lbs. and (2) 50lbs. acetylene cylinders and (2) 50 lbs. oxygen cylinders were not secured while in storage and could have been knocked over, on or about 03/29/202017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · F (O) $3803
- · C (S) $3803
- · Z (S) $3803
1917.152 D01 XVI
- Issued
- Jun 19, 2017
- Abate by
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1917.152(d)(1)(xvi): Oxygen cylinders were not separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes: a) FMC Garage - (2) 100 lbs. and (2) 50lbs. acetylene cylinders and (2) 50 lbs. oxygen cylinders were between 3 and 6 inches from one another, on or about 03/29/202017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · F (O) $0
- · C (S) $0
- · Z (S) $0
1917.156 A09
- Issued
- Jun 19, 2017
- Abate by
- Jun 23, 2017
- Penalty
- Initial $5,704 · Current $0 Reduced
General-duty citation text
29 CFR 1917.156(a)(9): Liquid fuel dispensing devices, such as pumps, were not mounted on a concrete island or otherwise protected against collision damage: a) Seagirt Terminal, Top Loader Compound - A 750 gallon gasoline dispensing container was not protected from physical damage, where vehicles including Hyster top loaders were parked, on or about 03/29/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · F (S) $0
- · C (S) $5704
- · Z (S) $5704
1910.1200 H01
- Issued
- Jun 19, 2017
- Abate by
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets: a) FMC Shop - A helper who uses CRC Brakleen part cleaner was not provided training regarding the use of hazardous chemicals in the shop, on or about 03/29/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 811111)
More inspections in MD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342216801.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.