Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: BLUEWATER SPORTFISHING BOATS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BLUEWATER SPORTFISHING BOATS INC. in 2901 INDUSTRIAL AVENUE 3, FORT PIERCE, FL 34946 (NAICS 336612). OSHA activity number 342227261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bluewater Sportfishing Boats INC. — free Get an email when a new federal OSHA severe-injury report for Bluewater Sportfishing Boats INC. is published. One employer, no account, unsubscribe in one click.
Site address
2901 INDUSTRIAL AVENUE 3
City
FORT PIERCE
State
FL
ZIP
34946
Mailing
2901 INDUSTRIAL AVENUE 3, FORT PIERCE, FL 34946
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
28
Ownership type
A

12 citations on file for this inspection.

1910.23 E01 V

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $4,183 · Current $2,510 Reduced
29 CFR 1910.23(e)(1)(v):  Unless otherwise specified in this section, mobile ladder stands and platforms with a top step height of 4 feet (1.2 m) or above did not have handrails with a vertical height of 29.5 inches (75 cm) to 37 inches (94 cm), measured from the front edge of a step (NOTE TO PARAGRAPH (e)(1)(v) OF THIS SECTION: Removable gates or non-rigid members, such as chains, may be used instead of handrails in special-use applications.)    On or about 4/5/2017, at the lamination department of the above addressed worksite, an employee was exposed to a fall hazard of 4'-4" while accessing a boat hull with a mobile ladder stand that lacked handrails.
Recent events (2)
  • — I (S) $2509.8
  • — Z (S) $4183

1910.106 E06 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jun 26, 2017
Penalty
Initial $4,183 · Current $2,510 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected:      On or about 4/5/2017, at the lamination department of the above addressed worksite, employees were exposed to a fire hazard while residual resin (DCPD Laminating Resin), contained in a 55-gallon drum was transferred to another drum without being electrically interconnected.
Recent events (2)
  • — I (S) $2509.8
  • — Z (S) $4183

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 16, 2017
Penalty
Initial $5,577 · Current $3,346 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about 4/5/2017, at the above addressed worksite, employees were exposed to struck and caught by hazards while operating a powered industrial truck (i.e. TCM Model FCG25F9, Maximum load 4600 lbs) without being trained and/or evaluated.
Recent events (2)
  • — I (S) $3346.2
  • — Z (S) $5577

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $5,577 · Current $3,346 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:     On or about 4/5/2017, at the finishing department of the above addressed worksite, an employee was exposed to an electrical hazard while using a fan which lacked of a ground prong on its attachment plug.
Recent events (2)
  • — I (S) $3346.2
  • — Z (S) $5577

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   On or about 4/5/2017, at the lamination department of the above addressed worksite, an electrical extension cord lacked of strain relief at the female end attachment plug, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jun 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about 4/5/2017, at the above addressed worksite, the employer did not make sure that equipment was inspected before use resulting in employees' exposure to electrical hazards, as evidenced by, among other conditions; fans that lacked of a ground prong on its attachment plug and/or had cord with broken outer insulation were used at the finishing department; a saw had been used with its cord outer insulation broken at the finishing department; and an electrical extension cord lacked of strain relief at the female end attachment plug at the laminating department.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Repeat Gravity 1 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $8,365 · Current $5,856 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about 4/5/2017, at the finishing department of the above addressed worksite, an employee was exposed to a caught by hazard while working with a sanding machine that lacked guards on in-running rolls.    Bluewater Sportfishing Boats Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 497598, citation number 1, item number 1 and was affirmed as a final order on 7/24/2012, with respect to a workplace located at 2901 Industrial Avenue 3, Fort Pierce, FL 34946.
Recent events (2)
  • — I (R) $5855.5
  • — Z (R) $8365

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Jun 16, 2017
Penalty
Initial $782 · Current $469 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    On or about 4/5/2017, at the lamination department of the above addressed worksite, exits were not marked exposing employees working in the area to a fire hazard.
Recent events (2)
  • — I (O) $469.2
  • — Z (O) $782

1910.179 G01 V

Other-than-serious 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:    On or about 4/5/2017, at the lamination department of the above addressed worksite, an employee was exposed to a struck-by hazard while operating a pendant control box for a hoisting mechanism whose push button were not marked.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 J02

Other-than-serious 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections:    On or about 4/5/2017, at the lamination department, frequent inspections of a crane were not conducted for identifying defects, including but not limited to; missing latches and/or deformations of hooks, and/or excessive wear of operating components.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 A

Other-than-serious 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:   On or about 4/5/2017, at the finishing department of the above addressed worksite, an air hose was repaired with tape, exposing employees to a struck by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about 4/5/2017, at the lamination department of the above addressed worksite, an electrical panel board was blocked, exposing an employee to a struck by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bluewater Sportfishing Boats INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342227261.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.