FORT LAUDERDALE, FL ·
OSHA Inspection: ARZOLA CONCRETE, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of ARZOLA CONCRETE, INC. in 307 SEVEN ISLES DRIVE, FORT LAUDERDALE, FL 33301 (NAICS 238140). OSHA activity number 342229291.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARZOLA CONCRETE, INC.
- Site address
- 307 SEVEN ISLES DRIVE
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33301
- Mailing
- 4832 WEYMOUTH ST, LAKE WORTH, FL 33463
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold not fully planked.
Recent events (1)
- · Z (S) $3803
1926.451 C02
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without base plates.
Recent events (1)
- · Z (S) $3803
1926.451 E01
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without and access ladder.
Recent events (1)
- · Z (S) $3803
1926.451 F04
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with bended bracing.
Recent events (1)
- · Z (S) $3803
1926.451 G04 I
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without guardrails.
Recent events (1)
- · Z (S) $3803
1926.451 H02 II
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold without toaboards.
Recent events (1)
- · Z (S) $3803
1926.452 C02
- Issued
- Aug 7, 2017
- Abate by
- Aug 17, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 4/04/2017, at the above addressed jobsite, employees were engaged in stucco work at approximately 14 feet from a scaffold with missing bracing.
Recent events (1)
- · Z (S) $3803
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342229291.