Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONTINENTAL TIRE NORTH AMERICA, INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CONTINENTAL TIRE NORTH AMERICA, INC in 11525 N ILLINOIS HWY 142, MOUNT VERNON, IL 62864 (NAICS 326211). OSHA activity number 342233525.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Continental Tire North America, INC — free Get an email when a new federal OSHA severe-injury report for Continental Tire North America, INC is published. One employer, no account, unsubscribe in one click.
Site address
11525 N ILLINOIS HWY 142
City
MOUNT VERNON
State
IL
ZIP
62864
Mailing
11525 N. ILLINOIS HIGHWAY 142, MOUNT VERNON, IL 62864
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326211
Employees
3082
Ownership type
A

3 citations on file for this inspection.

1910.147 F02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2017
Abate by
Oct 11, 2017
Penalty
Initial $9,054 · Current $12,675
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:   The employer contracted the services of HF Rubber Machinery, Inc. for the installation of the #17 TSR.   The employer and HF Rubber Machinery, Inc. did not inform each other of their respective hazardous energy control procedures.
Recent events (3)
  • — F (S) $12675
  • — C (S) $9054
  • — Z (S) $9054

1910.147 F03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2017
Abate by
Oct 11, 2017
Penalty
Initial $0 · Current $12,675
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department or other group:    On or about April 5, 2017, Continental Tire North America, Inc., did not ensure that the employees of its subcontractor HF Rubber Machinery, Inc. conducted group lock out tag out prior to engaging in the installation of the #17 TSR.
Recent events (3)
  • — F (S) $12675
  • — C (S) $0
  • — Z (S) $0

1910.147 D

Repeat Gravity 5 2 instances 2 exposed
Issued
Sep 14, 2017
Abate by
Oct 11, 2017
Penalty
Initial $90,540 · Current $12,675 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence:  a)  Employees were exposed to machine hazards associated with the uncontrolled electrical, pneumatic and gravitational energy when employees were engaged in service and maintenance activities on the #17 Inclined Batch Off Conveyor.  The employer failed to implement energy control application steps and ensure each authorized employee had the knowledge of the type, magnitude, the hazards, and the method or means to control energy prior to performing service work [per the 1910.147(d)(1)].  As a result, the remaining applicable energy control elements, involving equipment shutdown [(d)(2)], machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine service hazards.   b) Employees were exposed to machine hazards associated with the uncontrolled electrical and pneumatic energy when employees were engaged in service and maintenance activities on the #17 TSR.  The employer failed to implement energy control application steps as residual energy was not dissipated [per the 1910.147(d)(5)(i)].  As a result, the remaining applicable energy control elements, verification of isolation [(d)(6)], was not implemented to protect employees from machine service hazards.      The Continental Tire North America, Inc. was previously cited for a violation of this occupational safety and health standard 1910.147(d), which was contained in OSHA inspection number 1050581, citation number 1, item number 1a and was affirmed as a final order on February 8, 2016, with respect to a workplace located at 11525 North IL Hwy 142, Mount Vernon, IL.
Recent events (3)
  • — F (R) $12675
  • — C (R) $90540
  • — Z (R) $90540

View Continental Tire North America, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342233525.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.