CHICAGO, IL —
OSHA Inspection: MEYER STEEL DRUM, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of MEYER STEEL DRUM, INC. in 2000 S. KILBOURN AVE., CHICAGO, IL 60623 (NAICS 332439). OSHA activity number 342233939.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEYER STEEL DRUM, INC.
- Site address
- 2000 S. KILBOURN AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60623
- Mailing
- 2000 S. KILBOURN AVE., CHICAGO, IL 60623
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 66
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.217 C02 I D
- Issued
- Jul 25, 2017
- Abate by
- Aug 4, 2017
- Penalty
- Initial $8,963 · Current $3,137 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(d): Point of operation guard(s) on mechanical power press(es) did not utilized fasteners not readily removable by the operator, so as to create minimize the possibility of misuse or removal of essential parts: a. On or about April 6, 2017, on the L&J presses, the point of operation guards that are installed had fasteners (wing nuts and pins) that are readily removable by the operator, thereby exposing the employees to amputation hazards.
Recent events (2)
- — I (S) $3137.05
- — Z (S) $8963
1910.219 D01
- Issued
- Jul 25, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $8,963 · Current $3,137 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). a. On or about April 6, 2017, in the coil room, the guard that covered the belt and pulley on the Dayton Speedaire air compressor was not installed, thereby exposing employees to the hazards associated with moving machine parts.
Recent events (2)
- — I (S) $3137.05
- — Z (S) $8963
1910.219 E01 I
- Issued
- Jul 25, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a. On or about April 6, 2017, in the coil room, the guard that covered the belt and pulley on the Dayton Speedaire air compressor was not installed, thereby exposing employees to the hazards associated with moving machine parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jul 25, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $10,755 · Current $3,764 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about April 6, 2017, in the coil room , the electrical panel located behind the coiler did not have all opening effectively closed, thereby exposing employees to the hazards associated with electrical shock. b. On or about April 6, 2017, in the coil room, the electrical panel located next to the office/ break room did not have all opening effectively closed, thereby exposing employees to the hazards associated with electrical shock.
Recent events (2)
- — I (S) $3764.25
- — Z (S) $10755
1910.303 E01 II
- Issued
- Jul 25, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: Other markings giving voltage, current, wattage, or other ratings as necessary. a. On or about April 6, 2017, in the coil room the Square D electrical panels were not marked to indicate voltage, thereby exposing employees to the hazards of electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C02 I A
- Issued
- Jul 25, 2017
- Abate by
- Aug 4, 2017
- Penalty
- Initial $25,097 · Current $8,794 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s). a. On or About April 6, 2017, on the L&J presses serial numbers 52001 and 51966 , the point of operation of the presses were not fully guarded, thereby exposing employees to amputation hazards. The Meyer Steel Drum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.217(c)(2)(I)(a), which was contained in OSHA inspection number 1140927, citation number 1, item number 7 and was affirmed as a final order on August 11, 2016, with respect to a workplace located at 2000 S. Kilbourn, Chicago, IL 60623.
Recent events (2)
- — I (S) $8794
- — Z (R) $25097
More inspections at Meyer Steel Drum, INC.
View Meyer Steel Drum, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332439)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342233939.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.