Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HI-TEK MANUFACTURING INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HI-TEK MANUFACTURING INC. in 940 SNYDER ROAD, MASON, OH 45040 (NAICS 332710). OSHA activity number 342234945.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hi-Tek Manufacturing INC. — free Get an email when a new federal OSHA severe-injury report for Hi-Tek Manufacturing INC. is published. One employer, no account, unsubscribe in one click.
Site address
940 SNYDER ROAD
City
MASON
State
OH
ZIP
45040
Mailing
6050 HI-TEK COURT, MASON, OH 45040
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
205
Ownership type
A

2 citations on file for this inspection.

1910.217 C01 I

Serious Gravity 10 4 instances 1 exposed
Issued
Apr 28, 2017
Abate by
Jun 15, 2017
Penalty
Initial $11,408 · Current $2,500 Reduced
29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10.    a) On March 30, 2017 no point of operation guarding such as but not limited to; light curtains, two hand palm buttons, Type A or Type B gate was not in place on the Minster part revolution press #4  s/n 29064 operating in automatic mode to prevent employees exposure to the point of operation.    b) Located at 940 Snider Road, presses such as the Minster P2-60 #1, P2-60-42 #2, P2-100 #3 were not guarded to prevent employees exposure to the point of operation on each part revolution presses.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $11408

1910.217 E01 I

Serious Gravity 10 4 instances 4 exposed
Issued
Apr 28, 2017
Abate by
Jun 15, 2017
Penalty
Initial $11,408 · Current $2,500 Reduced
29 CFR 1910.217(e)(1)(i): It shall be the responsibility of the employer to establish and follow a program of periodic and regular inspections of his power presses to ensure that all their parts, auxiliary equipment, and safeguards are in a safe operating condition and adjustment. The employer shall maintain a certification record of inspections which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the power press that was inspected.      a) Press inspections conducted for the Minister part revolution presses were inadequate in that the inspections did not address the need for guarding while in automatic mode to prevent employees exposure to the point of operation.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $11408

View Hi-Tek Manufacturing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342234945.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.