OVERLAND PARK, KS ·
OSHA Inspection: ARROW J WELDING, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ARROW J WELDING, LLC. in 10521 W 113TH ST., OVERLAND PARK, KS 66221 (NAICS 238190). OSHA activity number 342240074.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARROW J WELDING, LLC.
- Site address
- 10521 W 113TH ST.
- City
- OVERLAND PARK
- State
- KS
- ZIP
- 66221
- Mailing
- 476 US HWY 160, SATANTA, KS 67870
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 1
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.352 E
- Issued
- Sep 14, 2017
- Abate by
- Sep 29, 2017
- Penalty
- Initial $3,803 · Current $1,902 Reduced
General-duty citation text
29 CFR 1926.352(e): When the welding, cutting or heating operation was such that normal fire prevention precautions were not sufficient, additional personnel were not assigned to guard against fire while the actual welding, cutting, or heating operation was being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire existed: At the jobsite located at 10501 W. 113th St., Overland Park, KS, employees engaged in construction activities in and around building 2 were exposed to fire and smoke inhalation hazards in that the following was not provided when normal fire prevention precautions were not sufficient: a) Employee(s) were not trained in the specific anticipated hazards associated with welding, cutting, and heating operations. b) Employee(s) were not provided training regarding the use of fire fighting equipment. c) The employer did not maintain a fire watch for sufficient period of time after the completion of work to ensure no possibility of fire existed.
Recent events (2)
- · I (S) $1901.5
- · Z (S) $3803
More inspections in this industry (NAICS 238190)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342240074.