Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CLIFTON HOME IMPROVEMENT LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CLIFTON HOME IMPROVEMENT LLC. in 20 MARINUS STREET, ROCHELLE PARK, NJ 07662 (NAICS 236118). OSHA activity number 342243276.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clifton Home Improvement LLC. for free Get an email when a new federal OSHA severe-injury report for Clifton Home Improvement LLC. is published. One employer, no account, unsubscribe in one click.
Site address
20 MARINUS STREET
City
ROCHELLE PARK
State
NJ
ZIP
07662
Mailing
34 VERNON AVE, CLIFTON, NJ 07011
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 26, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines.        a) Exterior Scaffold:  Employees working on a ladder jack scaffold that was placed less then 3ft from an energized electrical lines and exposing employees to an electrical shock hazard, on or about 4/12/17.
Recent events (1)
  • · Z (S) $4183

1926.451 G01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 26, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a)  Exterior Scaffold: Employees exposed to a fall hazard of approximately 20 feet while working from a ladder jack scaffold without fall protection system in place, on or about 4/12/17.
Recent events (1)
  • · Z (S) $4183

1926.452 K04

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(4): Ladders used to support ladder jacks shall be placed, fastened, or equipped with devices to prevent slipping.   a) Building Exterior: Employees  engage in residential  work were exposed to a fall hazard in excess of 20 feet while using a ladder jack scaffold that wasn't secure, on or about 4/12/17.
Recent events (1)
  • · Z (S) $0

1926.501 B11

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 26, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:   a) Building Exterior: An employee was exposed to a fall hazard of approximately 15 feet while engaged in roofing work on a steep roof without a fall protection system in place, on or about 4/12/2017.
Recent events (1)
  • · Z (S) $4183

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 26, 2017
Penalty
Initial $2,988 · Current $2,988
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  Building Exterior: An employee was exposed to fall hazard while using an extension ladder without the side rails extending 3 feet past the landing accessing the roof level, on or about 4/12/2017.
Recent events (1)
  • · Z (S) $2988

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Building Exterior/Front: An employee engaged in residential roof work was exposed to a fall  hazard in excess of 15 feet while using an "A" framed ladder in the closed position to access a roof, on or about 4/12/2017.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342243276.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.