Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDUSTRIAL PERFORMANCE GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INDUSTRIAL PERFORMANCE GROUP in 5409 NEWGARDEN ROAD (STATE ROUTE 9), SALEM, OH 44460 (NAICS 336212). OSHA activity number 342245552.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Performance Group — free Get an email when a new federal OSHA severe-injury report for Industrial Performance Group is published. One employer, no account, unsubscribe in one click.
Site address
5409 NEWGARDEN ROAD (STATE ROUTE 9)
City
SALEM
State
OH
ZIP
44460
Mailing
5409 NEWGARDEN ROAD (STATE ROUTE 9), SALEM, OH 44460
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.28 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2017
Penalty
Initial $5,070 · Current $2,535 Reduced
29 CFR 1910.28(c)(1): the employer did not protect employees from falling objects by erecting and installing toeboards to prevent objects from falling to a lower level:    On or about April 11, 2017, in building #1 there was an elevated work platform/walkway approximately 7 feet above the work floor that was above an employee work station and vending machine. The elevated work platform/walkway did not have a toeboard.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.29 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2017
Penalty
Initial $6,338 · Current $2,535 Reduced
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface:    On or about April 11, 2017, at the southeast corner in building #1 there was an elevated work platform/walkway approximately 7 feet above the work floor. The guardrailing system had a top handrail that was 30 inches above the walking working surface of the platform.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $6338

1910.29 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guiderail system and the walking-working surface:  On or about April 11, 2017, at the southeast corner in building #1 there was an elevated work platform/walkway approximately 7 feet above the work floor. The guardrailing system did not have midrails.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2017
Penalty
Initial $6,338 · Current $4,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about April 11, 2017, the following machinery was not properly safeguarded.    1. The Shop Fox vertical drill press in building #1 was not guarded for flying metal chips and rotating parts at the drill press chuck.    2. The Scotchman ironworker in building #4 was not guarded at the point of operation of the flat stock shear.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $6338

1910.37 B06

Other-than-serious 1 instance 2 exposed
Issued
Jul 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  On or before April 11, 2017, there was an exit discharge doorway on the west wall in building #1. The doorway had an emergency exit sign above the door that was an illumination fixture.  The fixture was not operable.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Industrial Performance Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342245552.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.