WATERTOWN, NY —
OSHA Inspection: CAPITAL CONSTRUCTION CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAPITAL CONSTRUCTION CORP. in 89 PUBLIC SQUARE, WATERTOWN, NY 13601 (NAICS 236220). OSHA activity number 342245719.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPITAL CONSTRUCTION CORP.
- Site address
- 89 PUBLIC SQUARE
- City
- WATERTOWN
- State
- NY
- ZIP
- 13601
- Mailing
- 17698 US ROUTE 11, WATERTOWN, NY 13601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.150 C01 I
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $2,173 · Current $333 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): Travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet: a) 89 Public Square, basement, on or about 3-31-17: Employees were walking and working in a basement, in the vicinity of combustible materials, and the travel distance to the nearest fire extinguisher was greater than 100 feet.
Recent events (3)
- — J (S) $333.34
- — C (S) $2173
- — Z (S) $2173
1926.150 C01 VIII
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: a) 89 Public Square, basement, on or about 3-31-17: Employees were walking and working in a basement, in the vicinity of combustible materials, with multiple fire extinguishers that had not been inspected.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.304 F
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $2,716 · Current $333 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) 89 Public Square, first floor, Spa space, on or about 3-31-17: One employee was operating a table saw for ripping purposes that was not equipped with a spreader. b) 89 Public Square, first floor, Spa space, on or about 3-31-17: One employee was operating a table saw for ripping purposes that was not equipped with non kick-back fingers or "dogs". c) 89 Public Square, first floor, Spa space, on or about 3-31-17: One employee was operating a table saw for ripping purposes that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
- — J (S) $333.33
- — C (S) $2716
- — Z (S) $2716
1926.304 I01
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) 89 Public Square, first floor, Spa space, on or about 3-31-17: One employee was operating a table saw for ripping purposes that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.1052 A03
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $2,173 · Current $333 Reduced
General-duty citation text
29 CFR 1926.1052(a)(3): Riser height and/or tread depth was not uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs: a) 89 Public Square, basement to Boiler Room, on or about 3-31-17: Employees were accessing a room using a stairway with varying and uneven riser heights, exposing the employees to a fall hazard of 30-1/2 inches.
Recent events (3)
- — J (S) $333.33
- — C (S) $2173
- — Z (S) $2173
1926.1052 C01 II
- Issued
- Apr 20, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) 89 Public Square, basement to Boiler Room, on or about 3-31-17: Employees were accessing a room using a stairway without a stair rail system on the open sides of the stairs, exposing the employees to a fall hazard of 30-1/2 inches.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Capital Construction Corp.
View Capital Construction Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342245719.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.