OSHA Inspection: TURNER STRATEGIC TECHNOLOGIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TURNER STRATEGIC TECHNOLOGIES in BUILDING 476 OLD WILLIAMSBURG RD, YORKTOWN, VA 23690 (NAICS 236210). OSHA activity number 342251022.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Turner Strategic Technologies — free Get an email when a new federal OSHA severe-injury report for Turner Strategic Technologies is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 476 OLD WILLIAMSBURG RD
City
YORKTOWN
State
VA
ZIP
23690
Mailing
7440 CENTRAL BUSINESS PARK DRIVE SUITE 100, NORFOLK, VA 23513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
45
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 28, 2017
Penalty
Initial $3,297 · Current $0 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a)    Naval Weapons Station, Building 479: On or about 04/14/2017, the 50 ft. red extension cord used for temporary power to energize a three-way GFCI pigtail, printer, radio, laptop computer and cell phone was not protected with a ground fault circuit interrupter device or an assured equipment grounding conductor program. The ground fault circuit interrupter used was not plugged directly into the permanent power of the building.       No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3297

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Apr 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a.)    Naval Weapons Station, Building 479: On or about 04/14/2017, the 50 ft. red extension cord used for temporary power to energize a three-way GFCI pigtail, printer, radio, laptop computer and cell phone, conductor wires at the male end were pulled away from the attachment plug thus caused strain on the internal terminals.     No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.150 C01 VIII

Deleted Other-than-serious 1 instance 4 exposed
Issued
Apr 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  a)    Naval Weapons Station, Building 479: On or about 04/14/2017,  three(3) ABC type fire extinguishers  were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, NFPA No.10A-1970.   No abatement certification or documentation required.  Note: Periodic inspection of fire extinguishers shall include a check of at least the following items and documented:   a)    Location in designated place. b)    No obstruction to access or visibility. c)    Operating instructions on nameplate legible and facing outward. d)    Safety seals and tamper indicators not broken or missing. e)    Pressure gauge reading or indicator in the operable range or position. f)     At least monthly, the date the inspection was performed and the initials of the person performing the inspection shall be recorded. g)    Records shall be kept on a tag or label attached to the fire extinguisher, on an inspection checklist maintained on file, or in an electronic system (e.g., bar coding) that provides a permanent record.