GAINESVILLE, FL —
OSHA Inspection: BNG CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BNG CONSTRUCTION, INC. in 3490 SW ARCHER ROAD, GAINESVILLE, FL 32608 (NAICS 238140). OSHA activity number 342257128.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BNG CONSTRUCTION, INC.
- Site address
- 3490 SW ARCHER ROAD
- City
- GAINESVILLE
- State
- FL
- ZIP
- 32608
- Mailing
- 2995 STONEWALL PLACE, SANFORD, FL 32773
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 C02
- Issued
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a. On or about April 12, 2017 employees were working in an excavation greater than 4-feet without a stairway, ladder, ramp or other safe means of egress within 25 feet.
Recent events (1)
- — Z (O) $0
1926.651 K01
- Issued
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a. On or about April 12, 2017, daily inspections were not made by a competent person, exposing employees to a cave-in hazard.
Recent events (1)
- — Z (O) $0
1926.651 J02
- Issued
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary: a. On or about April 12, 2017, employees were working in a 5.4-foot trench, where the spoil piles were placed on the leading edge of the trench, exposing employees to being struck by the material.
Recent events (1)
- — Z (O) $0
1926.652 A01
- Issued
- Jun 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a. On or about April 12, 2017, in a 5.4 foot deep trench, employees were not protected from cave-in from walls by the use of a protective system.
Recent events (1)
- — Z (O) $0
More inspections at BNG Construction, INC.
View BNG Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342257128.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.