OSHA Inspection: NATIONAL PARK SERVICE, FORT VANCOUVER NATIONAL HISTORIC SITE

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of NATIONAL PARK SERVICE, FORT VANCOUVER NATIONAL HISTORIC SITE in 612 EAST RESERVE STREET, VANCOUVER, WA 98661 (NAICS 712190). OSHA activity number 342259835.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service, Fort Vancouver National Historic Site — free Get an email when a new federal OSHA severe-injury report for National Park Service, Fort Vancouver National Historic Site is published. One employer, no account, unsubscribe in one click.
Site address
612 EAST RESERVE STREET
City
VANCOUVER
State
WA
ZIP
98661
Mailing
612 EAST RESERVE STREET, VANCOUVER, WA 98661
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
35
Ownership type
D

3 citations on file for this inspection.

1910.147 C01

Repeat Gravity 1 1 instance 8 exposed
Issued
Jun 16, 2017
Abate by
Aug 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  A)     The facility maintenance section did not have a completed energy control program in place.  The employer was able to provide a draft document that did not have any details specific to the work being done at the facility.  The National Park Service was previously cited for a violation of this standard, which was contained in OSHA inspection No. 1139555 citation 1 item 2, issued on June 3rd with respect to a workplace at the Fort Vancouver National Historic Site.
Recent events (1)
  • — Z (R) $0

1910.147 C04 I

Repeat Gravity 5 1 instance 8 exposed
Issued
Jun 16, 2017
Abate by
Aug 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  A)     In the employee maintenance facility, the employer did not have accurate specific procedures in place for the locking out of equipment.  The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 1139555, citation 2, item 1a, issued on June 3rd, 2016 with respect to a workplace at Vancouver, Washington  The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 1086975, citation 2, item 2a, issued on September 30th, 2015 with respect to a workplace at Marblemount, Washington.  The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 897353, citation 3, item 3, issued on May 14th, 2013 with respect to a workplace at Coulee Dam, Washington
Recent events (1)
  • — Z (R) $0

1910.215 B09

Repeat Gravity 5 2 instances 8 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  A)     In the metal shop, there were two bench grinders that did not have their tongue guards properly adjusted to within 1/4 inch of the grinding wheel.     The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 1139555, citation 2, item 3b, issued on June 3rd, 2016 with respect to a workplace in Vancouver, Washington.    The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 1086975, citation 2, item 3b, issued on September 30th, 2015 with respect to a workplace in Marblemount, Washington.    The national park service was previously cited for a violation of this standard which was contained in OSHA inspection No. 989415, citation 1, item 2, issued on September 19th, 2014 with respect to a workplace in Vancouver, Washington.