WASHINGTON, DC ·
OSHA Inspection: GJR MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GJR MASONRY, INC. in 4810 GLENBROOK RD NW, WASHINGTON, DC 20009 (NAICS 238140). OSHA activity number 342262383.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GJR MASONRY, INC.
- Site address
- 4810 GLENBROOK RD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 21122 HUNTINGTON SQ. APT. 100, STERLING, VA 20166
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 31, 2017
- Penalty
- Initial $3,259 · Current $3,259
General-duty citation text
1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about April 19, 2017; scaffold located on the North-side of building; an employee was operating a STIHL T5420 Concrete Saw without eye protection to prevent injury while cutting concrete block.
Recent events (3)
- · F (S) $3259
- · C (S) $3259
- · Z (S) $3259
1926.451 E01
- Issued
- Aug 31, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about April 19, 2017; scaffold located on the Northside of building; employees were using the scaffold frame and braces to access the working platform exposing employees to a 27-foot fall to ground level.
Recent events (3)
- · F (S) $3803
- · C (S) $3803
- · Z (S) $3803
1926.451 F07
- Issued
- Aug 31, 2017
- Abate by
- Sep 11, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) On or about April 19, 2017; scaffold located on the north-side of building; the employer did not have a competent person on site to ensure that the scaffold system had access provided to the working platform and measures taken to ensure that the employees are protected from falling 27-feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- · F (S) $3803
- · C (S) $3803
- · Z (S) $3803
1926.451 G01 VII
- Issued
- Aug 31, 2017
- Abate by
- Sep 11, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about April 19, 2017; scaffold located on the North-side of building; employees were not protected from falling 27-feet to ground level by a personal fall arrest system or guardrails while working on the open ends of the scaffold system. b) On or about April 19, 2017; scaffold located on the North-side of building; employees were working on a scaffold system in which the mid-rails were not installed exposing employees to a 27-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- · F (S) $3803
- · C (S) $3803
- · Z (S) $3803