LEWISTON, ME —
OSHA Inspection: NEOKRAFT SIGNS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEOKRAFT SIGNS, INC. in 686 MAIN ST, LEWISTON, ME 04240 (NAICS 339950). OSHA activity number 342262862.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEOKRAFT SIGNS, INC.
- Site address
- 686 MAIN ST
- City
- LEWISTON
- State
- ME
- ZIP
- 04240
- Mailing
- 686 MAIN ST, LEWISTON, ME 04240
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 34
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 15, 2017
- Abate by
- Aug 1, 2017
- Penalty
- Initial $8,873 · Current $4,436 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Facility - The Roper Whitney Autobrake was not equipped with machine guarding, such as a light curtain, to protect employees from the hazards created by point of operation.
Recent events (2)
- — I (S) $4436
- — Z (S) $8873
1910.1200 E01
- Issued
- Jun 15, 2017
- Abate by
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Facility - The employer did not develop or implement a written hazard communication program which complies with the 2012 Hazard Communication standard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Jun 15, 2017
- Abate by
- Jul 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: Facility - The employer did not have current safety data sheets for chemicals in use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Neokraft Signs, INC.
View Neokraft Signs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339950)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342262862.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.