OSHA Inspection: AMERICAN CAST IRON PIPE COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN CAST IRON PIPE COMPANY in 1501 31ST AVENUE NORTH, BIRMINGHAM, AL 35207 (NAICS 331511). OSHA activity number 342270857.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Cast Iron Pipe Company for free Get an email when a new federal OSHA severe-injury report for American Cast Iron Pipe Company is published. One employer, no account, unsubscribe in one click.
Site address
1501 31ST AVENUE NORTH
City
BIRMINGHAM
State
AL
ZIP
35207
Mailing
P.O. BOX 2727, BIRMINGHAM, AL 35202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
1445
Ownership type
Private (A)

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Sep 12, 2017
Abate by
Sep 22, 2017
Penalty
Initial $10,158 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to burn hazards:  (a) On or about 4/10/2017 - Ductile Pipe #1 Casting Area, trough operators receiving molten metal from iron pourers were exposed to molten metal that can overflow when being transferred from the Holding Ladle into the Quadrant Ladle.
Recent events (3)
  • · J (S) $0
  • · C (S) $10158
  • · Z (S) $10158

1910.132 A

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Sep 12, 2017
Abate by
Sep 22, 2017
Penalty
Initial $10,158 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  (a) On or about 4/10/2017 - Ductile Pipe #1 Casting Machine, employees working on the ductile iron pipe were not provided the appropriate spatter guards or "spats" for protection against molten iron at approximately 2600 degrees F.
Recent events (3)
  • · J (S) $0
  • · C (S) $10158
  • · Z (S) $10158

1910.132 D01

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Sep 12, 2017
Abate by
Sep 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  (a) On or about 4/10/2017 - Ductile Pipe #1 Casting Machine, the personal protective assessment for trough operators did not identify the appropriate foot protection including spatter guards or "spats" for employees exposed to molten metal at approximately 2600 degrees F when working on the ductile iron pipe.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

View American Cast Iron Pipe Company's full OSHA safety record →