Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: TURNER COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TURNER COMPANY in 11049 S US HWY 287, RHOME, TX 76078 (NAICS 327320). OSHA activity number 342273174.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Turner Company for free Get an email when a new federal OSHA severe-injury report for Turner Company is published. One employer, no account, unsubscribe in one click.
Establishment
TURNER COMPANY
Site address
11049 S US HWY 287
City
RHOME
State
TX
ZIP
76078
Mailing
11049 S US HWY 287, RHOME, TX 76078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 III A

Other-than-serious 1 instance 15 exposed
Issued
Jun 6, 2017
Abate by
Jul 31, 2017
Penalty
Initial $6,338 · Current $4,437 Reduced
29 CFR 1910.147(c)(7)(iii)(A): Retraining shall be provided for all authorized and affected employees whenever there is a change in their job assignments, a change in machines, equipment or processes that present a new hazard, or when there is a change in the energy control procedures.    On or about April 26, 2017 and a times prior thereto, the employer did not provide adequate or continued training for energy controls purpose, function, recognition of energy sources, removal and use of the energy control program and procedures exposing employees to electrical shock hazards.
Recent events (2)
  • · I (O) $4437
  • · Z (S) $6338

1910.147 D04 I

Other-than-serious 1 instance 8 exposed
Issued
Jun 6, 2017
Abate by
Jul 31, 2017
Penalty
Initial $6,338 · Current $4,437 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tag-out devices were not affixed to each energy isolating device by authorized employees:    In building #4, throughout the building, employees working on electrical wiring did not affix lockout devices to the circuit panels or breakers to prevent accidental reenergizing the circuit exposing employees to electrical shock hazards.
Recent events (2)
  • · I (O) $4437
  • · Z (S) $6338

1910.147 F02 I

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 6, 2017
Abate by
Jul 5, 2017
Penalty
Initial $6,338 · Current $0 Reduced
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:  On or before April 26, 2017 and at times prior thereto, the employer did not ensure outside contractors were following lock-out/tag-out procedures exposing them and other employees to electrical shock hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $6338

View Turner Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342273174.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.