CANTON, MA —
OSHA Inspection: BOYAJIAN INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOYAJIAN INC. in 144 WILL DRIVE, CANTON, MA 02021 (NAICS 311999). OSHA activity number 342274115.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOYAJIAN INC.
- Site address
- 144 WILL DRIVE
- City
- CANTON
- State
- MA
- ZIP
- 02021
- Mailing
- 144 WILL DRIVE, CANTON, MA 02021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- May 12, 2017
- Abate by
- Jul 3, 2017
- Penalty
- Initial $2,463 · Current $1,232 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Production Room: Pinchpoints at the capper section of the Dry Fill Line were not guarded.
Recent events (2)
- — I (S) $1231.5
- — Z (S) $2463
1910.147 C01
- Issued
- May 12, 2017
- Abate by
- Jul 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Worksite: The employer did not develop a written lockout tagout program.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- May 12, 2017
- Abate by
- Jul 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Training of operators of the high reach truck and the electric jack were last done over three years ago.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 311999)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342274115.