WAUSAU, WI —
OSHA Inspection: STEEL SHIELD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEEL SHIELD in 1508 MERRILL AVENUE, WAUSAU, WI 54401 (NAICS 238160). OSHA activity number 342275690.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEEL SHIELD
- Site address
- 1508 MERRILL AVENUE
- City
- WAUSAU
- State
- WI
- ZIP
- 54401
- Mailing
- 3700 COMBS CREEK LANE, STEVENS POINT, WI 54481
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B11
- Issued
- May 24, 2017
- Penalty
- Initial $3,803 · Current $1,902 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a) On or about April 25, 2017 at 1500 Merrill Avenue in Wausau, employees were working on a 6:12 pitched roof at 10 ft. above surface level without utilizing fall protection equipment.
Recent events (2)
- — I (S) $1901.5
- — Z (S) $3803
1926.1051 A
- Issued
- May 24, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. a) On or about April 25, 2017 at 1500 Merrill Avenue in Wausau, employees were using a self-supporting portable ladder to access a roof edge at 10 ft. above surface level with the top rung 22 in. below the upper landing surface.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1926.1053 B01
- Issued
- May 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about April 25, 2017 at 1500 Merrill Avenue in Wausau, employees were using a self-supporting portable ladder to access a roof edge at 10 ft. above surface level without a grabrail provided above the upper landing surface. The top of the ladder was below the roof edge and it was not secured.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- May 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step. a) On or about April 25, 2017 at 1500 Merrill Avenue in Wausau, employees were using the top rung of a self-supporting portable ladder when accessing/egressing a roof edge at 10 ft. above surface level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B20
- Issued
- May 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(20): When ascending or descending a ladder, the user shall face the ladder. a) On or about April 25, 2017 at 1500 Merrill Avenue in Wausau, an employee who was working on a roof surface 10 ft. above surface level was descending the roof access/egress ladder without facing the ladder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Steel Shield
View Steel Shield's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI