WALTON HILLS, OH —
OSHA Inspection: MASON STRUCTURAL STEEL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASON STRUCTURAL STEEL INC. in 7500 NORTHFIELD RD., WALTON HILLS, OH 44146 (NAICS 332312). OSHA activity number 342277357.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASON STRUCTURAL STEEL INC.
- Site address
- 7500 NORTHFIELD RD.
- City
- WALTON HILLS
- State
- OH
- ZIP
- 44146
- Mailing
- 7500 NORTHFIELD RD., WALTON HILLS, OH 44146
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 62
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C01
- Issued
- Jun 29, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative: On or about April 20, 2017, the employer failed to establish an effective program for the control of hazardous energy at the facility. Energy sources used at the facility include; but are not limited to, electric, hydraulic and pneumatic energy.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.157 E01
- Issued
- Jun 29, 2017
- Penalty
- Initial $3,802 · Current $1,901 Reduced
General-duty citation text
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: On or about April 20,2017, the employer did not perform annual inspections or testing of all portable fire extinguishers at the workplace. Fire extinguishers located throughout the production bays were not had not received there annual maintenance check. The last maintenance check(s) recorded on the service tag(s) was March of 2016.
Recent events (2)
- — I (S) $1901
- — Z (S) $3802
1910.157 G02
- Issued
- Jun 29, 2017
- Abate by
- Aug 16, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: Note: Applies where all employees are expected to fight fires. On or about April 20, 2017, employees working in the maintenance/service bay of the facility were not trained on fire extinguisher use for incipient stage fires on an annual basis. a) Note the employer may exercise one of the following options: 1. Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as specified in 29 CFR 1910.157(g). The other sections of 29 CFR also apply. 2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sound of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g). Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and 29 CFR 1910.39(a). Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to the use/storage of flammable/combustible liquids). If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Jun 29, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about April 20, 2017 and at times prior to, employees were allowed to operate powered industrial trucks (e.g. the company's LP forklift) at the site without having received formal instruction, including operator evaluation to determine the retention of the information.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.179 J02 III
- Issued
- Jun 29, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: On or about April 20, 2017, the employer did not ensure that hook inspections were performed and documented as required. Safety latches; affixed to the hooks/hoisting apparatus of the overhead bridge cranes located adjacent to the second bay (Fitting/Detailing) and in the 4th bay of the production area, were tied back with wiring. Employees performing crane operations are not protected from potential hazards created by accidental load disengagement.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.179 L03 III D
- Issued
- Jun 29, 2017
- Penalty
- Initial $3,802 · Current $1,901 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible: On or about April 20, 2017, the eight (8) push button pendant control remote used by an employee to operate the 10 ton overhead bridge crane located in bay 4, was missing some of the button covers and the labeling was not clearly marked to identify the directional and/or functionality (e.g.: North, South, Up and Down) of each button(s).
Recent events (2)
- — I (S) $1901
- — Z (S) $3802
1910.212 A01
- Issued
- Jun 29, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $6,338 · Current $3,169 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about April 20,2017, the employer failed to ensure that various equipment or machinery used at the site was effectively guarded. The unguarded equipment includes; but is not limited to, the following: a. The unused portion of the blade; on the backside of the Wellsaw (swivel) horizontal band saw model # 1316, located in the finishing/detail area of the facility was unguarded exposing employees to the rotating blade. b. The unused portion of the blade of the Wellsaw horizontal band saw, model # 1016 was unguarded, exposing the operator(s) to a point of operation hazard and/or unintentional contact with the rotating blade. c. Guarding to prevent entry into the rear of the (Cincinnati) press brake, the Betenbender Shear and the Piranha Shear, located in the second bay (Fitting and detailing area) was not installed.
Recent events (2)
- — I (S) $3169
- — Z (S) $6338
1910.303 B02
- Issued
- Jun 29, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about April 20,2017, the employer did not ensure that the three prong adapter located in the second bay area was installed according to the listing or labeling. The adapter (which was designed for house-hold use) was plugged into a 4 outlet junction box, and the electrical cords of various pieces of commercial equipment with varying amperages were plugged into it. The wiring system was not GFCI protected, thus employees and others working in the immediate area were exposed to potential hazards created by dropped voltage(s) or over-current relays.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.1200 E01
- Issued
- Jun 29, 2017
- Penalty
- Initial $3,802 · Current $1,901 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: The employer did not develop, implement, or maintain a written hazard communication program at the site. Chemicals used at the site include but are not limited; compressed gases (Acetylene, Oxygen), lubing oils, etc.
Recent events (2)
- — I (S) $1901
- — Z (S) $3802
1910.1200 H01
- Issued
- Jun 29, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Employees were not trained on the hazardous chemicals utilized in the workplace. Chemicals used at the site include; but are not limited to, compressed gases (Acetylene, Oxygen), lubing oils, etc.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Jun 29, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The employer did not train employees regarding the new label elements and safety data sheets format. On or about April 20, 2017, the employer failed to provide training or information to employees working with hazardous chemicals on the details of outline in the new hazard communication standard which encompasses the Global Harmonization System (GHS).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Mason Structural Steel INC.
View Mason Structural Steel INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342277357.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.