LAS VEGAS, NV —
OSHA Inspection: LAS VEGAS PAIUTE GOLF RESORT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LAS VEGAS PAIUTE GOLF RESORT in 10325 NU-WAV KAIV BLVD., LAS VEGAS, NV 89124 (NAICS 713910). OSHA activity number 342277647.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAS VEGAS PAIUTE GOLF RESORT
- Site address
- 10325 NU-WAV KAIV BLVD.
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89124
- Mailing
- 10325 NU-WAV KAIV BLVD., LAS VEGAS, NV 89124
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713910
- Employees
- 48
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.305 G02 III
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $2,473 · Current $2,473
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws. a) Northwest wall of the maintenance shop, the portable grinder's power cord had its outer sheathing separated from the conductors, employees were exposed to electrical hazards.
Recent events (1)
- — Z (S) $2473
1910.101 B
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): 29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P11965, as incorporated by reference in Sec. 1910.6: Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over. a) Inside the maintenance shop, oxygen and acetylene gas cylinders in storage were not properly secured, exposing employees to explosion or fire hazards.
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. a) North entrance of the maintenance shop, portable fire extinguisher was free standing and not mounted, exposing employees to smoke inhalation hazards.
Recent events (1)
- — Z (O) $0
1910.157 E02
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly a) North entrance of the maintenance shop, portable fire extinguisher was not inspected monthly, the last inspection date was April 19, 2016.
Recent events (1)
- — Z (O) $0
1910.243 C01
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4). a) Northwest wall of the maintenance shop, the portable grinder was used without a cup guard, employees were exposed to laceration hazards.
Recent events (1)
- — Z (O) $0
1910.253 B04 III
- Issued
- Aug 7, 2017
- Abate by
- Aug 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1/2 hour. a) Northwest wall of the maintenance shop, oxygen and acetylene gas cylinders were stored together, exposing employees to fire hazards or smoke hazards.
Recent events (1)
- — Z (O) $0
1910.1200 E01 I
- Issued
- Aug 7, 2017
- Abate by
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer's written hazard communication program did not include a list of the hazardous chemicals known to be present at the workplace. a) At the maintenance shop, there was no complete inventory of all chemicals used by employees such as RL -pro solvent, Toro-fuel treatment and Carb X. Employees were exposed to chemical hazards.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Aug 7, 2017
- Abate by
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. a) At the maintenance shop, there was no safety data sheets of all chemicals used by employees such as RL -pro solvent, Toro-fuel treatment and Carb X. Employees were exposed to chemical hazards.
Recent events (1)
- — Z (O) $0
More inspections at LAS Vegas Paiute Golf Resort
View LAS Vegas Paiute Golf Resort's full OSHA safety record →
More inspections in this industry (NAICS 713910)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342277647.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.