Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCGEE ROOFING LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MCGEE ROOFING LLC in 1203 RIDGE CIR., TONGANOXIE, KS 66086 (NAICS 238160). OSHA activity number 342277803.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcgee Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Mcgee Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MCGEE ROOFING LLC
Site address
1203 RIDGE CIR.
City
TONGANOXIE
State
KS
ZIP
66086
Mailing
1961 NAVAJO ROAD, CLAY CENTER, KS 67432
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
14
Ownership type
A

8 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 10, 2017
Abate by
Jan 15, 2018
Penalty
Initial $2,173 · Current $1,738 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  The employer is failing to protect employees from exposure to chemical hazards.  This was most recently documented on or about May 2, 2017 at the jobsite located at 1203 Ridge Circle, Tonganoxie, Kansas.  The employer did not develop or implement a written hazard communication program to address the hazards of hazardous chemicals being used by employees on the jobsite, such as but not limited to gasoline, liquid petroleum gas, and other roofing materials and adhesives.
Recent events (2)
  • — I (S) $1738.4
  • — Z (S) $2173

1910.1200 H01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Oct 10, 2017
Abate by
Nov 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):  Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets:      The employer is failing to protect employees from exposure to chemical hazards.  This was most recently documented on or about May 2, 2017 at the jobsite located at 1203 Ridge Circle, Tonganoxie, Kansas.  Employees were exposed to health hazards in that  they were not trained on hazardous chemicals used on the jobsite, such as but not limited to gasoline, liquid petroleum gas, and other roofing materials and adhesives.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 A01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Oct 10, 2017
Abate by
Nov 3, 2017
Penalty
Initial $5,070 · Current $0 Reduced
29 CFR 1926.416(a)(1): Employee(s) were permitted to work in proximity to electric power circuits that were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  The employer is failing to protect employees from electrical hazards while engaged in residential roofing activities.  This was most recently documented on or about May 2, 2017 at the jobsite located at 1203 Ridge Circle, Tonganoxie, Kansas.  Employees were working near 240 volt energized electrical power lines, exposing employees to electrical shock hazards while performing residential re-roofing activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5070

1926.416 A03

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 10, 2017
Abate by
Jan 15, 2018
Penalty
Initial $0 · Current $4,056
29 CFR 1926.416(a)(3): Before work was begun the employer did not ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit; the employer did not post and maintain proper warning signs where such a circuit existed; and the employer did not advise employees of the location of such lines, the hazards involved, and the protective measures to be taken:  The employer is failing to protect employees from electrical hazards while engaged in residential roofing activities.  This was most recently documented on or about May 2, 2017 at the jobsite located  1203 Ridge Circle, Tonganoxie, Kansas.  The employer did not take necessary actions to ascertain the presence of, or warn employees of energized 240 volt electrical wiring and advise employees on actions needed to be taken to avoid potential contact. Employees were exposed to electrical shock/electrocution hazards.
Recent events (2)
  • — I (S) $4056
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 10, 2017
Abate by
Jan 15, 2018
Penalty
Initial $5,070 · Current $4,056 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   The employer is failing to protect the employees from fall hazards while engaged in residential roofing activities.  This was most recently documented on or about May 2, 2017 at the jobsite located at 1203 Ridge Circle, Tonganoxie, Kansas. An employee engaged in residential roofing activities, tearing off shingles from a 4:12 pitch roof was exposed to fall hazards of approximately 20 feet from the roof's eave to the ground.
Recent events (2)
  • — I (S) $4056
  • — Z (S) $5070

1926.502 D16 III

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 10, 2017
Abate by
Jan 15, 2018
Penalty
Initial $5,070 · Current $0 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, was not rigged such that an employee could neither free fall more than 6 feet (1.8 m), nor contact any lower level:  The employer is failing to protect employees from fall hazards while performing residential re-roofing activities.  This was most recently documented on or about May 2, 2017 at the jobsite located at 1203 Ridge Circle, Tonganoxie, Kansas. Employees engaged in residential roofing activities, tearing off shingles from a 4:12 pitch roof was exposed to a fall hazard of approximately 20 feet from the roof's eave to the ground in that employees did not properly adjust the fall arrest system from the lanyard to the anchor point on the peak of the roof.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5070

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 10, 2017
Abate by
Jan 15, 2018
Penalty
Initial $5,070 · Current $4,056 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program did not enable each employee to recognize the hazards of falling and did not train each employee in the procedures to be followed in order to minimize these hazards:  The employer is failing to protect employees from exposure to fall hazards while performing residential reroofing activities.  This was most recently documented on May 2, 2017, in that the employer did not provide adequate training to each employee on the procedures to be followed for the correct use and operation of fall arrest systems, to include but not limited to the proper use of anchor points, and the proper adjustment of fall arrest systems.
Recent events (2)
  • — I (S) $4056
  • — Z (S) $5070

1926.503 B01

Deleted Other-than-serious 1 instance 4 exposed
Issued
Oct 10, 2017
Abate by
Nov 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record.   The employer is failing to provide upon request a certification of fall protection training for all employees engaged in reroofing activities.   This was most recently documented on May 2, 2017, at the jobsite located at 1203 Ridge Cir., in Tonganoxie, Kansas.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mcgee Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342277803.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.