OVERTON, NV —
OSHA Inspection: NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - ECHO BAY WATER TREATMENT PLANT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - ECHO BAY WATER TREATMENT PLANT in BUILDING 642 ECHO BAY ROAD, OVERTON, NV 89040 (NAICS 712190). OSHA activity number 342281292.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - ECHO BAY WATER TREATMENT PLANT
- Site address
- BUILDING 642 ECHO BAY ROAD
- City
- OVERTON
- State
- NV
- ZIP
- 89040
- Mailing
- 601 NEVADA WAY, BOULDER CITY, NV 89005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 5
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.147 C04
- Issued
- Aug 29, 2017
- Abate by
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Lift Station: Employees exposed to struck by hazards from hydraulic or pneumatic energy by employer failing to protect from hazardous energy sources on lift station during service and maintenance without procedures.
Recent events (1)
- — Z (S) $0
1910.147 C07 I
- Issued
- Aug 29, 2017
- Abate by
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage , and removal of energy controls were acquired by employees: Lift Station: Employees exposed to struck by hazards from hydraulic or pneumatic energy by employer failing to provide training on procedures to protect from hazardous energy sources on lift station during service and maintenance.
Recent events (1)
- — Z (S) $0
1910.36 D01
- Issued
- Aug 29, 2017
- Abate by
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors: Chemical Storage Room: Employees are exposed to becoming entrapped in the event of a fire due to the designated exit door leading to exit discharge could not be opened due to failure of dead bolt to open when attempting to open door. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 913208, CITATION 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 12, 2013, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, ASH MOUNTAIN NATIONAL PARK, 47050 GENERALS HIGHWAY, THREE RIVERS, CALIFORNIA 93271.
Recent events (1)
- — Z (R) $0
1910.242 B
- Issued
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: West Wall: Employees were exposed to flying parts and pieces and air embolisms while using an air nozzle with approximately 95 p.s.i. of unregulated air at the nozzle. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1165213, CITATION 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 6, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, SEQUOIA AND KINGS CANYON, WOLVERTON WATER TREATMENT FACILITY, SEQUOIA NATIONAL PARK, CALIFORNIA 93262.
Recent events (1)
- — Z (R) $0
1910.305 J02 IV
- Issued
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: East Wall Roll-up Door: Employees were exposed to electric shock/fire hazards due to electrical outlet located below water faucet that was not protected by GFCI. THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1086115, CITATION 01, ITEM NUMBER 006 AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 10, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, 1 BLACK CANYON ROAD, ESSEX, CALIFORNIA 92332
Recent events (1)
- — Z (R) $0
More inspections at National Park Service, Lake Mead National Recreation Area - Echo BAY Water Treatment Plant
More inspections in this industry (NAICS 712190)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342281292.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.