OSHA Inspection: NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - COTTONWOOD COVE FIRE STATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, LAKE MEAD NATIONAL RECREATION AREA - COTTONWOOD COVE FIRE STATION in BUILDING 242 COTTONWOOD COVE ROAD, SEARCHLIGHT, NV 89046 (NAICS 922160). OSHA activity number 342281524.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service, Lake Mead National Recreation Area - Cottonwood Cove Fire Station — free Get an email when a new federal OSHA severe-injury report for National Park Service, Lake Mead National Recreation Area - Cottonwood Cove Fire Station is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 242 COTTONWOOD COVE ROAD
City
SEARCHLIGHT
State
NV
ZIP
89046
Mailing
601 NEVADA WAY, BOULDER CITY, NV 89005
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922160
Employees
5
Ownership type
D

2 citations on file for this inspection.

1910.28 B01 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 19, 2017
Abate by
Nov 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system:  Balcony, Building 242: Employees exposed to a fall of approximately eight feet two inches to the concrete floor below through a six feet ten inch opening on the balcony. The mid-rail for the opening is missing.
Recent events (1)
  • — Z (S) $0

1910.305 J02 IV

Repeat Gravity 5 2 instances 5 exposed
Issued
Oct 19, 2017
Abate by
Nov 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:   (a) Engine Bay, Building 242 (Washer/Dryer): Employees were exposed to electric shock/fire hazards due to electrical outlet that was not protected by GFCI that was being with Roper by Whirlpool Washer/Dryer.    (b) Engine Bay, Building 242 (Sink): Employees were exposed to electric shock/fire hazards due to electrical outlet that was not protected by GFCI that was being used when floor is wet.    THE U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1086115, CITATION 01, ITEM NUMBER 006 AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 10, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, 1 BLACK CANYON ROAD, ESSEX, CALIFORNIA 92332