GREENVILLE, IL —
OSHA Inspection: PETERSON AMERICAN CORPORATION DBA PETERSON SPRINGS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PETERSON AMERICAN CORPORATION DBA PETERSON SPRINGS in 1375 PETERSON INDUSTRIAL DRIVE, GREENVILLE, IL 62246 (NAICS 332612). OSHA activity number 342287968.
Where did this inspection happen?
- Establishment
- PETERSON AMERICAN CORPORATION DBA PETERSON SPRINGS
- Site address
- 1375 PETERSON INDUSTRIAL DRIVE
- City
- GREENVILLE
- State
- IL
- ZIP
- 62246
- Mailing
- 1375 PETERSON INDUSTRIAL DRIVE, GREENVILLE, IL 62246
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332612
- Employees
- 34
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 26, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $9,054 · Current $5,885 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Procedures were not developed, and documented to control potential hazardous energy while an employee conducts set up work on a Sleeper & Harley Series 322 Press.
Recent events (2)
- — I (S) $5885.1
- — Z (S) $9054
1910.147 C06 I
- Issued
- Jun 26, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $9,054 · Current $5,885 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: The employer did not conduct an annual inspection of the energy control procedures to ensure that machines such as Sleeper & Harley Series 322 had specific procedures to control possible hazardous energy sources.
Recent events (2)
- — I (S) $5885.1
- — Z (S) $9054
1910.217 C01 I
- Issued
- Jun 26, 2017
- Abate by
- Aug 31, 2017
- Penalty
- Initial $9,054 · Current $5,885 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): Employees were not protected by guarding or properly applied point of operation devices to address point of operation hazards while operating a Trim and Loop Press.
Recent events (2)
- — I (S) $5885.1
- — Z (S) $9054
1910.303 B02
- Issued
- Jun 26, 2017
- Penalty
- Initial $9,054 · Current $5,885 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employees were exposed to a 480 volt electrical shock when electrical power was supplied by a pendent box that did not have approved strain-relief connectors where the cord entered the box.
Recent events (2)
- — I (S) $5885.1
- — Z (S) $9054
More inspections at Peterson American Corporation DBA Peterson Springs
View Peterson American Corporation DBA Peterson Springs's full OSHA safety record →
More inspections in this industry (NAICS 332612)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342287968.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.