Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: NATAZ SPECIALTY COATINGS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NATAZ SPECIALTY COATINGS, INC. in 3300 W. 31ST STREET, CHICAGO, IL 60623 (NAICS 324122). OSHA activity number 342293735.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nataz Specialty Coatings, INC. for free Get an email when a new federal OSHA severe-injury report for Nataz Specialty Coatings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3300 W. 31ST STREET
City
CHICAGO
State
IL
ZIP
60623
Mailing
3300 W. 31ST STREET, CHICAGO, IL 60623
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324122
Employees
20
Ownership type
Private (A)

6 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $3,622 · Current $2,535 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following; a guardrail system, safety net system or a personal fall protection system:   a) On or about May  3, 2017, at the above located workplace, employees  were required to add cellulose and clay to the product while working on a work platform  on the second level. The work platform had an open side without a guardrail (or the equivalent). The employees were thereby exposed to a fall hazard of approximately 10-12 feet.
Recent events (2)
  • · I (S) $2535.4
  • · Z (S) $3622

1910.28 B06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $3,622 · Current $2,535 Reduced
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment was not protected from falling by a guardrail system or a travel restraint system when the equipment was not covered or guarded to eliminated the hazard:    a) On or about May  3, 2017, at the above located workplace, employees were required to work around a 3.0 feet by X 3 feet floor opening. The floor opening was over an uncovered horizontal ribbon mixer. The mixer's ribbons were less than 1 foot below floor level. The employees were thereby exposed to fall hazards and/or crushing hazards.
Recent events (2)
  • · I (S) $2535.4
  • · Z (S) $3622

1910.29 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $2,897 · Current $2,028 Reduced
29 CFR 1910.29(b)(1): The employer did not ensure that each guard rail system had a top edge height of top rails, or equivalent guardrail system members, that was 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface:     a) On or about May 3, 2017, at the above located workplace, employees on the second level just west of the horizontal ribbon mixer were required to work on an open-sided floor which had a top rail that was 30 inches above the floor. Employees were thereby exposed to a fall hazard of approximately 10 feet.
Recent events (2)
  • · I (S) $2027.9
  • · Z (S) $2897

1910.29 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2): The employer did not ensure that each guard rail system had a  midrail, screen, mesh, intermediate vertical member, solid panel, or equivalent intermediate member installed between the walking-working surface and the top edge of the guardrail system:   a) On or about May 3, 2017, at the above located workplace, employees on the second level were required to work at and around a stairway's floor opening. The floor opening guardrail did not have a  midrail, screen, mesh, intermediate vertical member, solid panel, or equivalent intermediate member installed between the walking-working surface and the top edge of the guardrail system. The employees were thereby exposed to a fall hazard of approximately 10 feet.     b)On or about May 3, 2017, at the above located workplace, employees on the second level were required to work just south west of the stairway. The guardrail on the south side of the platform did not have a midrail, screen, mesh, intermediate vertical member, solid panel, or equivalent intermediate member installed between the walking-working surface and the top edge of the guardrail system. The employees were thereby exposed to a fall hazard of approximately 10 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.29 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(10): In a hoist area the employer used chains that did not provide a level of safety equivalent to guardrails:    a) On or about May 3, 2017, at the above located workplace, employees were required to work in the hoist area just north of where cellulose and clay were added to the product. The hoist area floor edge was guarded with a single chain that did not provide employee safety equivalent to guardrails. The employees were thereby exposed to a fall hazard of approximately 10 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Aug 3, 2017
Abate by
Aug 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) On or about May 3, 2017, employees working with asphalt and asphalt ingredients were provided N 95 filtering facepiece respirators for voluntary use. The employer did not provide the information contained in 29 CFR 1910.134, Appendix D ("Information for Employees Using Respirators When Not Required Under the Standard").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342293735.