Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VISCUSI BUILDERS LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VISCUSI BUILDERS LTD. in VILLAGE AT SHAKER CREEK ROUTE 9, LOUDONVILLE, NY 12211 (NAICS 236117). OSHA activity number 342295581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Viscusi Builders LTD. — free Get an email when a new federal OSHA severe-injury report for Viscusi Builders LTD. is published. One employer, no account, unsubscribe in one click.
Site address
VILLAGE AT SHAKER CREEK ROUTE 9
City
LOUDONVILLE
State
NY
ZIP
12211
Mailing
14 AVALON WAY, ALTAMONT, NY 12009
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.150 A01

Other-than-serious 1 instance 12 exposed
Issued
Jun 6, 2017
Abate by
Jun 14, 2017
Penalty
Initial $2,173 · Current $1,086 Reduced
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equiment as specified in this subpart:    (a) Village at Shaker Creek (all buildings under construction):   On or prior to 5/3/17, a fire protection program was not established for the jobsite.
Recent events (2)
  • — I (O) $1086
  • — Z (S) $2173

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 6, 2017
Penalty
Initial $2,897 · Current $1,738 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       (a) 4248 Cambridge way:  On or prior to 5/3/17, OSB guardrails for elevator shaft openings were not secured at the opening.
Recent events (2)
  • — I (S) $1738.2
  • — Z (S) $2897

1926.1052 C01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 6, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    (a) 4248 Cambridge Way:  On or prior to 5/3/17, basement entry stairs were not equipped with at least one handrail.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1926.404 B01 I

Other-than-serious 1 instance 10 exposed
Issued
Jun 6, 2017
Abate by
Jun 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  (a)  137 Sudbury and 4248 Cambridge Way:  On or prior to 5/3/17, 120V, 15A duplex receptacles provided for use as temporary power (ocated next to the panel box in each unit) were not equipped with GFCI protection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 B02

Other-than-serious 5 instances 10 exposed
Issued
Jun 6, 2017
Abate by
Jun 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  (a) 137 Sudbury and 4248 Cambridge way:   On or prior to 5/3/17, 120V, energized 15A receptacles installed next to panel box(es) in each unit were not equipped with faceplates.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Viscusi Builders LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342295581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.